Influence of physiological noise on accelerated 2D and 3D resting state functional MRI data at 7 T.
نویسندگان
چکیده
PURPOSE Physiological noise often dominates the blood-oxygen level-dependent (BOLD) signal fluctuations in high-field functional MRI (fMRI) data. Therefore, to optimize fMRI protocols, it becomes crucial to investigate how physiological signal fluctuations impact various acquisition and reconstruction schemes at different acquisition speeds. In particular, further differences can arise between 2D and 3D fMRI acquisitions due to different encoding strategies, thereby impacting fMRI sensitivity in potentially significant ways. METHODS The amount of physiological noise to be removed from the BOLD fMRI signal acquired at 7 T was quantified for different sampling rates (repetition time from 3300 to 350 ms, acceleration 1 to 8) and techniques dedicated to fast fMRI (simultaneous multislice echo planar imaging [EPI] and 3D EPI). Resting state fMRI (rsfMRI) performances were evaluated using temporal signal-to-noise ratio (tSNR) and network characterization based on seed correlation and independent component analysis. RESULTS Overall, acceleration enhanced tSNR and rsfMRI metrics. 3D EPI benefited the most from physiological noise removal at long repetition times. Differences between 2D and 3D encoding strategies disappeared at high acceleration factors (6- to 8-fold). CONCLUSION After physiological noise correction, 2D- and 3D-accelerated sequences provide similar performances at high fields, both in terms of tSNR and resting state network identification and characterization. Magn Reson Med 78:888-896, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
منابع مشابه
High Temporal Resolution Functional Magnetic Resonance Imaging at 7 Tesla
Speed has always been a critical consideration in magnetic resonance imaging (MRI), promising dramatic gains in imaging speed, a reduction in motion and susceptibility artifacts, and ultimately increased throughput for clinical studies. In the context of functional magnetic resonance imaging (fMRI), MRI pulse sequences designed to increase the speed and spatial resolution have always been a top...
متن کاملThree dimensional echo-planar imaging at 7 Tesla
Functional MRI (fMRI) most commonly employs 2D echo-planar imaging (EPI). The advantages for fMRI brought about by the increasingly popular ultra-high field strengths are best exploited in high-resolution acquisitions, but here 2D EPI becomes impractical for several reasons, including the very long volume acquisitions times. In this study at 7 T, a 3D EPI sequence with full parallel and partial...
متن کاملBrain Activity Map Extraction of Neuromyelitis Optica Patients Using Resting-State fMRI Data Based on Amplitude of Low Frequency Fluctuations and Regional Homogeneity Analysis
Introduction: Neuromyelitis Optica (NMO) is a rare inflammatory disease of the central nervous system which generally affecting the spinal cord and optic nerve. Damage to the optic nerve can result in the patient's dim vision or even blindness, while the spinal cord damage may lead to sensory and motor paralysis and the weakness of the lower limbs in the patient. Magnetic Reson...
متن کاملImproved temporal resolution for functional studies with reduced number of segments with three-dimensional echo planar imaging.
PURPOSE To introduce a new k-space traversal strategy for segmented three-dimensional echo planar imaging (3D EPI) that encodes two partitions per radiofrequency excitation, effectively reducing the number excitations used to acquire a 3D EPI dataset by half. METHODS The strategy was evaluated in the context of functional MRI applications for: image quality compared with segmented 3D EPI, tem...
متن کاملSources of signal fluctuations in fMRI at 7 Tesla
The development of high-field magnetic resonance imaging (MRI) systems has allowed for critical improvements in image signal-to-noise ratio (SNR), potentially leading to higher sensitivity and spatial resolution for functional MRI (fMRI) techniques. However, recent studies have shown that these potential advantages become significantly compromised by increased signal fluctuations arising from c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 78 3 شماره
صفحات -
تاریخ انتشار 2017