Indoor glutaraldehyde levels in the endoscope disinfecting room and subjective symptoms among workers.

نویسندگان

  • Hiroshi Katagiri
  • Toshio Suzuki
  • Yoshiharu Aizawa
  • Takehiro Kadowaki
چکیده

We measured the environmental glutaraldehyde (GA) levels during the disinfection of endoscopes and also investigated the subjective symptoms of the workers engaged in that work. At 6 hospitals in the Tokyo and Kanagawa area, 8 rooms for endoscope washing and disinfecting the endoscopy equipment were surveyed. The geometric mean environmental GA levels in the 8 rooms were 1.3 to 19.6 ppb. The personal exposure levels at the time of replacing the antiseptic solution containing GA in two of the disinfecting rooms were 94.2 and 84.9 ppb. Subjective symptoms such as ophthalmic, nasal, respiratory, pharyngeal symptoms and nausea were more prevalent among workers than controls as evidenced from the questionnaire survey.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New disinfecting apparatus for gastrointestinal fibre-endoscopes.

Bacterial contamination of gastrointestinal fibre-endoscopes is a potential source of clinically significant infection. Aqueous 2% alkaline glutaraldehyde adequately disinfects fibre-endoscopes but may cause serious sensitivity reactions among endoscopy staff. A new 'closed-system' disinfecting apparatus is described that disinfects with glutaraldehyde for 30 minutes before an endoscopy session...

متن کامل

Disinfection of upper gastrointestinal fibreoptic endoscopy equipment: an evaluation of a cetrimide chlorhexidine solution and glutaraldehyde.

There is little information available on the bacteriological contamination of upper gastrointestinal fibreoptic endoscopes during routine use and the effects of 'disinfecting solutions'. A bacteriological evaluation was therefore made of cleaning an endoscope and its ancillary equipment with (1) water, (2) an aqueous solution of 1% cetrimide with 0.1% chlorhexidine, and (3) activated aqueous 2%...

متن کامل

Respiratory symptoms and bronchial responsiveness among cleaning and disinfecting workers in the food industry.

OBJECTIVES To measure the levels of exposure to nitrogen trichloride (NCl3) and aldehydes among cleaning and disinfecting workers in the atmosphere of food industry plants during cleaning and disinfecting operations, and to examine how they relate to irritant and chronic respiratory symptoms-which are indices of pulmonary function-and bronchial hyperresponsiveness (BHR) to methacholine. METHO...

متن کامل

مطالعه علائم سندرم ساختمان بیمار در کارکنان اداری سازمان بهداشت و درمان صنعت نفت

  Background­ and objectives : Research has consistently shown that air quality personal factors and work related factors were the most effective parameters for sick building syndrome. Several epidemiological studies have been carried out to show the prevalence of the sick building syndrome among the office workers but less attention has been paid to the relation of the sick building s...

متن کامل

The effect of indoor office environment on the work performance, health and well-being of office workers

BACKGROUND The effect of indoor environment may have an influence on the performance, productivity health and well-being of office workers. METHODS Environmental factors such as indoor temperature and illumination have been investigated at three levels. A neurobehavioral test (NBT) has been proposed for the evaluation of office workersc performance. A field lab to emulate an office has been c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Industrial health

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2006