X-ray microtomography in biology.
نویسندگان
چکیده
Progress in high-resolution X-ray microtomography has provided us with a practical approach to determining three-dimensional (3D) structures of opaque samples at micrometer to submicrometer resolution. In this review, we give an introduction to hard X-ray microtomography and its application to the visualization of 3D structures of biological soft tissues. Practical aspects of sample preparation, handling, data collection, 3D reconstruction, and structure analysis are described. Furthermore, different sample contrasting methods are approached in detail. Examples of microtomographic studies are overviewed to present an outline of biological applications of X-ray microtomography. We also provide perspectives of biological microtomography as the convergence of sciences in X-ray optics, biology, and structural analysis.
منابع مشابه
Phase-contrast X-ray microtomography of mouse fetus
A phase-contrast X-ray microtomography system using the Talbot imaging has been built at the SPring-8 synchrotron radiation facility. This system has much higher density resolution than absorption-based X-ray microtomography. The tomographic sections of formalin-fixed mouse fetuses obtained with this method clearly depict various organs without any staining at a pixel resolution of up to 5 µm. ...
متن کاملHigh resolution three-dimensional visualization and characterization of coronary atherosclerosis in vitro by synchrotron radiation x-ray microtomography and highly localized x-ray diffraction.
Human atherosclerotic plaques in both native and bypass arteries have been visualized using microtomography to provide additional information on the nature of coronary artery disease. Plaques contained within arteries removed from three white males aged 51, 55 and 70 are imaged in three-dimensions with monochromatic synchrotron x-ray radiation. Fields of view are 658 x 658 x 517 voxels. with cu...
متن کامل3-D Imaging Tomography with Sub-micrometer Resolution Using Fresnel Zone Plate Optics
X-ray microtomography has been developed for use in various fields such as biology, materials science, petrology, and medical diagnosis. This method’s setup commonly consists of a simple projection geometry with a high-resolution imaging detector and a highly collimated beam, e .g . , a microfocussing X-ray tube or synchrotron radiation source, which can result in a spatial resolution of about ...
متن کاملHigh-resolution X-ray microtomography is a sensitive method to detect vascular calcification in living rats with chronic renal failure.
OBJECTIVE Chronic renal failure (CRF) is associated with a 10- to 20-fold increase in cardiovascular risk. Vascular calcification is a prominent feature of cardiovascular disease in patients with end-stage renal failure and contributes to the excess mortality in this population. In this study, we explored in vivo X-ray microtomography (micro-CT) as a tool to detect and follow-up vascular calcif...
متن کاملThree-dimensional Mapping of Fatigue Crack Position via a Novel X-ray Phase Contrast Approach
X-ray absorption microtomography loses considerable sensitivity when it is applied to samples with high-aspect-ratio cross-sections, e.g. plates or compact tension samples. Synchrotron X-ray phase enhanced imaging is much more sensitive than absorption-based techniques to cracks with small openings, and phase imaging and stereometric techniques are developed in this paper for three-dimensional ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Micron
دوره 43 2-3 شماره
صفحات -
تاریخ انتشار 2012