New functional polar maps for estimating regional cardiac function using ECG-gated technetium-99m-tetrofosmin SPECT.

نویسندگان

  • M Onoguchi
  • H Maruno
  • T Takayama
  • Y Naoi
  • M Irimoto
  • N Maehara
  • H Katayama
  • H Murata
چکیده

OBJECTIVE The purpose of this work was to develop functional parameters to analyze regional cardiac function using ECG-gated 99mTc-tetrofosmin SPECT. Our goal was to develop a methodology that used slice thickness correction, the generation of a time-activity curve and a polar map. METHODS Fourteen normal patients without evidence of coronary artery disease were studied. One hour after intravenous injection of 740-1110 MBq (20-30 mCi) 99mTc-tetrofosmin, ECG-gated SPECT data were acquired by dividing a cardiac cycle into 12 frames. The SPECT data were reconstructed from 11 of 12 frames into 3 views. The reconstruction of these images was repeated after performing slice thickness correction. Excluding the effect of different apex-to-base lengths at any frame during a cardiac cycle, 10 short-axis images with the same slice thickness were obtained. Each short-axis image was divided by 40 radii into 40 segments. The time-activity curve was generated from the total counts included in each segment plus both neighboring segments. Subsequently the curve fitting was performed using the second Fourier function. RESULTS From fitted curves and their differentials, we calculated end-systolic count, end-diastolic count, percent count increase, uptake, peak contraction rate, peak distention rate and contraction time. CONCLUSION The functional polar maps visually demonstrated regional myocardial function. This method is expected to be helpful for assessing regional cardiac function using 99mTc-tetrofosmin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of left ventricular function using electrocardiographically gated myocardial SPECT with (123)I-labeled fatty acid analog.

UNLABELLED Electrocardiographically (ECG) gated myocardial SPECT with (99m)Tc-tetrofosmin has been used widely to assess left ventricular (LV) function. However, the accuracy of variables using ECG gated myocardial SPECT with beta-methyl-p-(123)I-iodophenylpentadecanoic acid (BMIPP) has not been well defined. METHODS Thirty-six patients (29 men, 7 women; mean age, 61.6 +/- 15.6 y) with ischem...

متن کامل

Detection of a biphasic response of hibernating myocardium by dobutamine-stress electrocardiography-gated technetium-99m-tetrofosmin single photon emission computed tomography--a case report.

A woman with coronary artery disease underwent a new imaging technique: dobutamine-stress electrocardiography (ECG)-gated tetrofosmin-single photon emission computed tomography (SPECT). Dobutamine-stress ECG-gated tetrofosmin-SPECT with automatic left ventricular function analysis software programs detected improvement and a biphasic response of dysfunctional myocardium during dobutamine infusi...

متن کامل

The additive prognostic value of perfusion and functional data assessed by quantitative gated SPECT in women.

BACKGROUND The aim of this study was to assess the prognostic value of technetium-99m tetrofosmin gated SPECT imaging in women using quantitative gated single photon emission computed tomography (SPECT) imaging. METHODS We followed 453 consecutive female patients. Average follow-up was 1.33 years (max. 2.55). Hard endpoints were cardiac death, acute myocardial infarction, or documented ventri...

متن کامل

Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging.

BACKGROUND Whether left ventricular function can be assessed accurately by gated single photon emission computed tomography (SPECT) in patients with myocardial infarction and severe perfusion defects is not well known. METHODS AND RESULTS Twenty-five patients with an acute myocardial infarction underwent 99mTc-labeled tetrofosmin (99mTc-tetrofosmin) gated SPECT and cine magnetic resonance ima...

متن کامل

Clinical value of acute rest technetium-99m tetrofosmin tomographic myocardial perfusion imaging in patients with acute chest pain and nondiagnostic electrocardiograms.

OBJECTIVES We sought to evaluate the clinical use and cost-analysis of acute rest technetium-99m (Tc-99m) tetrofosmin single-photon emission computed tomographic (SPECT) myocardial perfusion imaging in patients with chest pain and a normal electrocardiogram (ECG). BACKGROUND Current approaches used in emergency departments (EDs) for treating patients presenting with chest pain and a nondiagno...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2000