Evaluation of different computed tomography techniques and myelography for the diagnosis of acute canine myelopathy.

نویسندگان

  • Sophie E Dennison
  • Randi Drees
  • Helena Rylander
  • Brian S Yandell
  • Milan Milovancev
  • Roger Pettigrew
  • Tobias Schwarz
چکیده

Forty-six dogs with either cervical (C1-C5 or C6-T2) or thoracolumbar (T3-L3) acute myelopathy underwent prospective conventional computed tomography (CT), angiographic CT, myelography, and CT myelography. Findings were confirmed at either surgery or necropsy. Seventy-eight percent of lesions were extradural, 11% were extradural with an intramedullary abnormality, 7% were intramedullary, 2% were intradural-extramedullary, and 2% had nerve root compression without spinal cord compression. Intervertebral disc herniation was the most frequent abnormality regardless of signalment or neurolocalization. Twenty-one of 23 Hansen type I disc extrusions but none of the Hansen type II disc protrusions were mineralized. Two chondrodystrophic dogs had acute myelopathy attributable to extradural hemorrhage and subarachnoid cyst. CT myelography had the highest interobserver agreement, was the most sensitive technique for identification of compression, demonstrating lesions in 8% of dogs interpreted as normal from myelography and enabling localization and lateralization in 8% of lesions incompletely localized on myelography due to concurrent spinal cord swelling. None of the imaging techniques evaluated permitted definitive diagnosis of spinal cord infarction or meningomyelitis but myelography and CT myelography did rule out a surgical lesion in those cases. While conventional CT was adequate for the diagnosis and localization of mineralized Hansen type I disc extrusions in chondrodystrophic breeds, if no lesion was identified, plegia was present due to concurrent extradural compression and spinal cord swelling, or the dog was nonchondrodystrophic, CT myelography was often necessary for correct diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines

Introduction: Maxillary canines have important roles in facial appearance, development of arch, and functional occlusion. Radiographs are important in evaluating the location and nature of these anomalies. The purpose of this study was to evaluate two types of 2D and 3D imaging technique in diagnosis and treatment of maxillary impacted canines. Methods: Thirty eight patients (50 impacted canine...

متن کامل

Comparison of computed tomographic and cytological results in evaluation of normal prostate, prostatitis and benign prostatic hyperplasia in dogs

Prostate gland can be structurally evaluated by computed tomography (CT) with taking advantages of tomographic feature and post-contrast parenchymal changes. The current examination initiated to determine association between computed tomographic and cytological results in evaluation of canine prostate. Thirty mature male dogs were included and under gone by both CT and fine needle sampling of p...

متن کامل

A comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study

Introduction: Diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. Hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the diagnosis of mandibular bone defects present in sheep. Material & Methods: T...

متن کامل

Absorbed dose of sensitive organs in maxillofacial region by different radiographic techniques: Panoramic, Waters, Caldwell and cone-beam computed tomography

BACKGROUND AND AIM: Due to increasing use of X-rays in diagnosis and treatment of diseases, this study aimed to measure and compares the absorbed dose in a number of sensitive organs of head and neck in different radiographic techniques.METHODS: Thermoluminescence dosimeter (TLD) and a male equivalent RANDO phantom were used to measure the absorbed dose in organs. The dosimeters were set in cer...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association

دوره 51 3  شماره 

صفحات  -

تاریخ انتشار 2010