Combined Near-Infrared Spectroscopy and Intravascular Ultrasound Imaging of Pre-Existing Coronary Artery Stents: Can Near-Infrared Spectroscopy Reliably Detect Neoatherosclerosis?

نویسندگان

  • Ryan D Madder
  • Mohsin Khan
  • Mustafa Husaini
  • Margaret Chi
  • Sarah Dionne
  • Stacie VanOosterhout
  • Andrew Borgman
  • J Stewart Collins
  • Mark Jacoby
چکیده

BACKGROUND Neoatherosclerosis is an emerging phenomenon in which lipid-rich plaques (LRPs) develop within pre-existing stents. This study was undertaken to describe near-infrared spectroscopy (NIRS) and intravascular ultrasound findings in pre-existing stents and to compare NIRS findings in pre-existing stents, in which an increased lipid signal has been speculated to indicate neoatherosclerosis, and NIRS findings in a control group of freshly implanted stents, in which any lipid signal originates from fibroatheroma under the stent. METHODS AND RESULTS At the site of LRP detected by NIRS in a cohort of pre-existing stents, intravascular ultrasound was used to determine the presence of neointimal tissue. The lipid-core burden index and maximum lipid-core burden index in 4 mm were measured within stented segments. Findings were compared between pre-existing stents and a control group of freshly implanted stents. Among 60 pre-existing stents implanted 5.5±4.0 years earlier, NIRS detected LRP in 33%. At the site of LRP, intravascular ultrasound found no neointimal tissue in 35% of cases. NIRS findings in pre-existing stents were indistinguishable from those of freshly implanted stents (lipid-core burden index: 50±72 versus 42±58; P=0.40 and maximum lipid-core burden index in 4 mm: 156±184 versus 155±203; P=0.69). CONCLUSIONS The detection of LRP in a pre-existing stent by NIRS alone is not reliable evidence of neoatherosclerosis, as the lipid signal may originate from fibroatheroma underlying the stent. By identifying the presence or absence of neointimal tissue at the site of LRP detected by NIRS, intravascular ultrasound may provide some insight into the potential source of the lipid signal in pre-existing stents. REGISTRATION INFORMATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01694368.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter by Shaikh and Budoff Regarding Article, "Multimodality Intracoronary Imaging With Near-Infrared Spectroscopy and Intravascular Ultrasound in Asymptomatic Individuals With High Calcium Scores".

BACKGROUND This study sought to determine the frequency of large lipid-rich plaques (LRP) in the coronary arteries of individuals with high coronary artery calcium scores (CACS) and to determine whether the CACS correlates with coronary lipid burden. METHODS AND RESULTS Combined near-infrared spectroscopy and intravascular ultrasound was performed in 57 vessels in 20 asymptomatic individuals ...

متن کامل

Contemporary Reviews in Interventional Cardiology Advances in Intravascular Imaging

This review updates the role of various intravascular imaging techniques (1) in the detection of vulnerable plaque and (2) during percutaneous coronary intervention (PCI), especially drug-eluting stent (DES) implantation and follow-up—including intravascular ultrasound (IVUS), virtual histology (VH-IVUS) and integrated backscatter (IBIVUS), optical coherent tomography (OCT), near-infrared (NIR)...

متن کامل

Imaging of high-risk plaque.

'High-risk' or 'vulnerable' plaques in the coronary arteries have characteristics that make them more prone to disruption and subsequent thrombosis -- the mechanisms of most acute coronary syndromes (ACS). There are a number of imaging modalities that are capable of visualizing these features. This article discusses invasive modalities for identifying 'high-risk' plaque such as intravascular ul...

متن کامل

Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy

BACKGROUND In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible isc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2016