Relationship Between Anticoagulation Intensity and Thrombotic or Bleeding Outcomes Among Outpatients With Continuous-Flow Left Ventricular Assist Devices.
نویسندگان
چکیده
BACKGROUND We evaluated thrombotic and bleeding outcomes in patients with continuous-flow left ventricular assist devices (CF-LVADs), stratified by anticoagulation intensity. Previous studies of outpatients with CF-LVADs have suggested that target international normalized ratio (INR) values <2.5 (range, 2-3) may be used. However, recent studies reported an increase in pump thrombosis among CF-LVADs, especially within the first 6 months of implant. METHODS AND RESULTS We retrospectively reviewed 249 outpatients at our center who received a CF-LVAD between January 2005 and August 2013. Using Poisson models, we analyzed their 10 927 INRs to determine INR-specific rates of thrombotic (ischemic stroke and suspected pump thrombosis) and hemorrhagic (gastrointestinal bleeding and hemorrhagic stroke) events occurring outside of the hospital. In multivariate analyses, we adjusted for age, sex, atrial fibrillation, coronary disease, and LVAD type as time-dependent Cox proportional hazard models. During a mean follow-up of 17.6±13.6 months, thrombotic events occurred in 46 outpatients. The highest event rate (0.40 thrombotic events per patient-year) was in the INR range of <1.5, but INR values of 1.5 to 1.99 also had high rates (0.16 thrombotic events per patient-year). INR was inversely associated with thrombotic events (hazard ratio, 0.40; 95% confidence interval, 0.22-0.72; P=0.002). The optimal INR based on weighted mortality of thrombotic and bleeding events was 2.6. CONCLUSIONS INR is inversely related to thrombotic events occurring outside of the hospital among patients supported with CF-LVADs. INR values <2.0 increase the rate of thrombotic events occurring outside of the hospital among patients supported with CF-LVADs.
منابع مشابه
Gold standard in anticoagulation assessment of left ventricular assist device patients?: how about bronze.
SEE PAGE 314 C ontinuous-flow left ventricular assist devices (CF-LVADs) have become a standard therapeutic option in the management of eligible patients with advanced forms of heart failure. Although survival after LVAD implant has improved dramatically in the past decade, the cumulative incidence of LVAD-related adverse events is still high (1). Systemic anticoagulation is recommended in all ...
متن کاملPre-operative risk factors of bleeding and stroke during left ventricular assist device support: an analysis of more than 900 HeartMate II outpatients.
OBJECTIVES This study sought to determine the pre-operative risk factors related to late bleeding, stroke, and pump thrombosis in patients with HeartMate II (HMII) left ventricular assist devices (LVADs) (Thoratec Corporation, Pleasanton, California) that might influence tailored improvements in patient management. BACKGROUND Adverse events in LVAD patients remain high. It is unclear whether ...
متن کاملLetter by Jennings regarding article, "Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices".
Axial-flow LVADs have become an integral tool in the management of end-stage heart failure. Consequently, nonsurgical bleeding has emerged as a major source of morbidity and mortality in this fragile population. The mechanisms responsible for these adverse events include acquired von Willebrand disease, GI tract angiodysplasia formation, impaired platelet aggregation, and overuse of anticoagula...
متن کاملConcise Definitive Review
158 www.ccmjournal.org January 2014 • Volume 42 • Number 1 Objectives: To review left ventricular assist device physiology, initial postoperative management, common complications, trouble shooting and management of hypotension, and other common ICU problems. Data Source: Narrative review of relevant medical literature. Data Synthesis: Left ventricular assist devices prolong the lives of patient...
متن کاملClinical outcomes after continuous-flow left ventricular assist device: a systematic review.
BACKGROUND Conveying the complex trade-offs of continuous-flow left ventricular assist devices is challenging and made more difficult by absence of an evidence summary for the full range of possible outcomes. We aimed to summarize the current evidence on outcomes of continuous-flow left ventricular assist devices. METHODS AND RESULTS PubMed and Cochrane Library were searched from January 2007...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Heart failure
دوره 9 5 شماره
صفحات -