Residential indoor PM2.5 in wood stove homes: follow-up of the Libby changeout program.
نویسندگان
چکیده
UNLABELLED In 2005 through 2008, a small rural mountain valley community engaged in a woodstove changeout program to address concerns of poor ambient air quality. During this program, we assessed changes to indoor air quality before and after the introduction of a new, lower emission woodstove. We previously reported a >70% reduction in indoor PM(2.5) concentrations in homes following the installation of a new Environmental Protection Agency's-certified stove within the home. We report here on follow-up of the experiences in these and other homes over three winters of sample collection. In 21 homes, we compared pre-changeout PM(2.5) concentrations [mean (s.d.) = 45.0 (33.0) μg/m(3)] to multiple post-changeout measures of PM(2.5) concentrations using a DustTrak. The mean reduction (and 95% confidence interval) from pre-changeout to post-changeout was -18.5 μg/m(3) (-31.9, -5.2), adjusting for ambient PM(2.5) , ambient temperature, and other factors. Findings across homes and across years were highly variable, and a subset of homes did not experience a reduction in PM(2.5) following changeout. Reductions were also observed for organic carbon, elemental carbon, and levoglucosan, but increases were observed for dehydroabietic acid and abietic acid. Despite overall improvements in indoor air quality, the varied response across homes may be due to factors other than the introduction of a new woodstove. PRACTICAL IMPLICATIONS Biomass combustion is a common source of ambient PM(2.5) in many cold-climate communities. The replacement of older model woodstoves with newer technology woodstoves is a potential intervention strategy to improve air quality in these communities. In addition to ambient air, woodstove changeouts should improve residential indoor air quality. We present results from a multi-winter study to evaluate the efficacy of woodstove changeouts on improving indoor air quality. Reductions in indoor PM(2.5) were evident, but this observation was not consistent across all homes. These findings suggest that other factors beyond the introduction of an improved wood burning device are relevant to improving indoor air quality in wood burning homes.
منابع مشابه
Assessing the impact of a wood stove replacement program on air quality and children's health.
Many rural mountain valley communities experience elevated ambient levels of fine particulate matter (PM*) in the winter, because of contributions from residential wood-burning appliances and sustained temperature inversion periods during the cold season. A wood stove change-out program was implemented in a community heavily affected by wood-smoke-derived PM2.5 (PM < or = 2.5 microm in aerodyna...
متن کاملParticulate Matter 2.5 Exposure and Self-Reported Use of Wood Stoves and Other Indoor Combustion Sources in Urban Nonsmoking Homes in Norway
Few studies have examined particulate matter (PM) exposure from self-reported use of wood stoves and other indoor combustion sources in urban settings in developed countries. We measured concentrations of indoor PM < 2.5 microns (PM2.5) for one week with the MicroPEM™ nephelometer in 36 households in the greater Oslo, Norway metropolitan area. We examined indoor PM2.5 levels in relation to use ...
متن کاملCommunity woodstove changeout and impact on ambient concentrations of polycyclic aromatic hydrocarbons and phenolics.
A large woodstove changeout program was carried out in Libby, Montana, with the goal of reducing ambient levels of PM2.5. This provided researchers the opportunity to measure ambient concentrations of phenolic and polycyclic aromatic hydrocarbons (PAHs) before, during, and after the changeout of nearly 1200 stoves to evaluate the effectiveness of the intervention. Starting in the heating season...
متن کاملEvaluation of Potential Average Daily Doses (ADDs) of PM2.5 for Homemakers Conducting Pan-Frying Inside Ordinary Homes under Four Ventilation Conditions
Several studies reported that commercial barbecue restaurants likely contribute to the indoor emission of particulate matters with a diameter of 2.5 micrometers or less (PM2.5) while pan-frying meat. However, there is inadequate knowledge of exposure level to indoor PM2.5 in homes and the contribution of a typical indoor pan-frying event. We measured the indoor PM2.5 concentration and, using Mo...
متن کاملCarbon monoxide as a tracer for assessing exposures to particulate matter in wood and gas cookstove households of highland Guatemala.
Kitchen-area 22-h gravimetric PM2.5 and passive diffusion stain-tube carbon monoxide (CO) concentrations were measured in homes with open fire and improved wood cookstoves in two studies. In the first study (Guat-2), which also studied homes with gas cookstoves, three samples were collected per stove condition from each of three test houses. In the second study (Guat-3), one sample was collecte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indoor air
دوره 22 6 شماره
صفحات -
تاریخ انتشار 2012