Onset of pulsatile pressure causes transiently increased filtration through artery wall.

نویسندگان

  • Jonathan P Alberding
  • Ann L Baldwin
  • Jennifer K Barton
  • Elizabeth Wiley
چکیده

Convective fluid motion through artery walls aids in the transvascular transport of macromolecules. Although many measurements of convective filtration have been reported, they were all obtained under constant transmural pressure. However, arterial pressure in vivo is pulsatile. Therefore, experiments were designed to compare filtration under steady and pulsatile pressure conditions. Rabbit carotid arteries were cannulated and excised from male New Zealand White rabbits anesthetized with pentobarbitol sodium (30 mg/kg i.v. administered). Hydraulic conductance was measured in cannulated excised rabbit carotid arteries at steady pressure. Next, pulsatile pressure trains were applied within the same vessels, and, simultaneously, arterial distension was monitored using Optical coherence tomography (OCT). For each pulse train, the volume of fluid lost through filtration was measured (subtracting volume change due to residual distension) and compared with that predicted from steady pressure measurements. At 60- and 80-mmHg baseline pressures, the experimental filtration volumes were significantly increased compared with those predicted for steady pressure (P < 0.05). OCT demonstrated that the excess fluid volume loss was significantly greater than the volume that would be lost through residual distension (P < 0.05). After 30 s, the magnitude of the excess of fluid loss was reduced. These results suggest that sudden onset of pulsatile pressure may cause changes in arterial interstitial hydration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of pulsation frequency and endothelial integrity on enhanced arterial transmural filtration produced by pulsatile pressure.

The role of the endothelium in regulating transmural fluid filtration into the artery wall under pulsatile pressure and the effects of changes in pulsatile frequency on filtration have received little attention. Previous experiments (Alberding JP, Baldwin AL, Barton JK, and Wiley E. Am J Physiol Heart Circ Physiol 286: H1827-H1835, 2004) demonstrated significantly increased filtration after ini...

متن کامل

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 286 5  شماره 

صفحات  -

تاریخ انتشار 2004