Cannulated screw and hexapodal fixator reconstruction for compound upper tibial fractures

نویسندگان

  • Metin Uzun
  • Fikri Erkal Bilen
  • Levent Eralp
چکیده

OBJECTIVES The aim of the treatment of tibial plateau fractures is to obtain a pain-free and fully functional knee with closed reduction, percutaneous cannulated screw fixation and hexapodal external fixator reconstruction for high energy compound upper tibial fractures. METHODS Patients with comminuted tibial plateau fractures underwent closed reduction, percutaneous fixation with cannulated screws, and reconstruction with hexapodal external fixator. The follow-up period was 24 months. RESULTS The clinical and radiological results were good or excellent. The average knee flexion was 125°. CONCLUSION Our results are successful in the initial stage, however, it should be pointed out that during the long term follow-up osteoarthritis may develop leading to worsening of the condition. Level of Evidence IV, Case Series.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

متن کامل

Bicondylar tibial plateau fractures treated with fine-wire circular external fixation

Bicondylar tibial plateau fractures are serious injuries to a major weight-bearing joint. These injuries are often associated with severe soft tissue injuries that complicate surgical management. We reviewed 54 consecutive patients who sustained bicondylar tibial plateau fractures that were treated with limited open reduction and cannulated screw fixation combined with fine-wire circular extern...

متن کامل

Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws.

The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking ...

متن کامل

A biomechanical study comparing two fixation methods in depression fractures of the lateral tibial plateau in porcine bone

BACKGROUND A novel method of fixation has been described for the treatment of pure depression fractures of the lateral tibial plateau. Fracture fragments are elevated through a reamed transtibial tunnel. An interference screw is then passed into the tunnel to buttress fracture fragments from beneath. This method of fixation has perceived benefits but there have been no studies to demonstrate th...

متن کامل

Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report

INTRODUCTION High energy tibial plateau fractures along with calcaneal fractures individually produce several challenges for the orthopaedic surgeon. The principles of bony reconstruction include anatomic reduction and rigid internal fixation of intra-articular fractures and accurate restoration of the coronal, sagittal and transverse mechanical axes. Due to the tenuous nature of the soft tissu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2014