Characterization of interfacial socket pressure in transhumeral prostheses: A case series

نویسندگان

  • Jonathon S Schofield
  • Katherine R Schoepp
  • Heather E Williams
  • Jason P Carey
  • Paul D Marasco
  • Jacqueline S Hebert
چکیده

One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user's morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant Survival, Adverse Events, and Bone Remodeling of Osseointegrated Percutaneous Implants for Transhumeral Amputees

BACKGROUND Osseointegrated percutaneous implants provide direct anchorage of the limb prosthesis to the residual limb. These implants have been used for the rehabilitation of transhumeral amputees in Sweden since 1995 using a two-stage surgical approach with a 6-month interval between the stages, but results on implant survival, adverse events, and radiologic signs of osseointegration and adapt...

متن کامل

Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure

BACKGROUND The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. METHODS The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral use...

متن کامل

مقایسه میزان رضایت بیماران از اندازه‌های ابعادی سوکت در 3 روش قالب‌گیری پروتز

    Below knee amputation, which is noticed as one of the most common lower extremity amputations, is caused as a result of various factors like trauma, disease, or congenital limb deficiencies. In order to take these amputees back to daily life, below knee prostheses are used as an alternate to original limb. Comfort and patients’ satisfaction with prostheses are directly related to each prost...

متن کامل

Expert opinions on success factors for upper-limb prostheses.

The goal of this study was to gather the opinions of prosthetics experts on the most important factors for the successful use of upper-limb (UL) prostheses, compare them with those of prosthesis users, and ultimately direct research efforts in this field. UL prosthetics experts were asked to compare the importance of the comfort, function, and cosmesis of a prosthetic device for a transhumeral ...

متن کامل

Development of a Pattern Recognition-based Myoelectric Transhumeral Prosthesis with Multifunctional Simultaneous Control Using a Model-driven Approach for Mechatronic Systems

Modern components and materials in combination with recent pattern recognition methods for electromyographic (EMG) signals enable creating multi-functional arm prostheses with intelligent and user-friendly control [1]. While the usage of pattern recognition of features extracted from EMG signals has proven highly efficient in transradial prostheses [2,3], most current transhumeral prostheses ut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017