The Investigation of the Thermoluminescence Emission Bands of LiF:Mg,Ti (TLD-100) by a Simple Developed Model

نویسندگان

  • A. N. YAZICI
  • Z. ÖZTÜRK
  • M. BEDİR
چکیده

In this study, a new simple model based on the classical treatment of lattice vibrations and the Franck-Condon principle is developed to describe the shape of thermoluminescence (TL) emission bands of crystalline solids. According to developed model, shape of the emission band has a Gaussian form and depends on just two physical parameters: peak energy E0 and broadening of emission spectra U. In order to demonstrate the success of the developed model, the emission spectra of dosimetric material LiF:Mg,Ti (TLD-100) was also measured. Then, a computerised best-fit program including the developed model was used to analyse the emission spectra. The number of individual bands and their kinetic parameters were also obtained by this program. Two emission bands were observed for all glow peaks with peak energies at around 3.0 eV and 2.75 eV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین پارامترهای فروکشی دمایی دزیمتر ترمولومینسانس (TLD-100) LiF:Mg,Ti

Thermal quenching is a known and important effect which should be taken into account in studying thermoluminescence (TL) phenomenon. This effect causes the probability of non-radiative recombinations to be increased with raising temperature in TL process. This article deals with changes of the TL glow curve of LiF:Mg, Ti (TLD-100) with heating rate. It was observed that the main dosimetry peak ...

متن کامل

Evaluation of the Entrance Skin Dose in Animals Undergoing Diagnostic Radiology Using LiF, Mg, Ti Thermoluminescence Dosimetry (TLD-100)

Introduction According to the International Commission on Radiological Protection publication numbers 60 and 21, the environmental control standards should ensure human and other species protection to a desirable degree. Since application of radiographic procedures in Veterinary Medicine has increased significantly, in this study, we aimed to evaluate the entrance skin dose to the animals (e.g....

متن کامل

بررسی اثر رژیم گرمایی روی طیف تابش LiF:Mg,Cu,P و مقایسه با LiF:P

Thermoluminescence material LiF:Mg,Cu,P was produced using standard GR200 dopant concentrations and its emission and absorption spectrums was measured after beta irradiation. The alterations resulting from various thermal treatments, excessing the recommended temperatures namely 240ºC on the emission and absorption spectrums has been investigated. The main peak of absorption spectrum, which is ...

متن کامل

بررسی و تحلیل منحنی‏های پاسخ پودر فلورید لیتیوم (LiF:Mg,Ti) در مش‏های مختلف برای پرتو گاما به‌ منظور استفاده در دزیمتری ترمولومینسانس

The effect of the different parameters on the thermoluminescence behavior of LiF:Mg,Ti powder produced by melting method is reported. Standard powder of LiF:Mg,Ti manufactured by Harshaw company, was converted to smaller grains size, to obtain different meshes after melting and cooling steps. Powder in this study are of mesh size: 80 to 100, 120 to 140 and 170 to 200 µm. The results show that ...

متن کامل

Investigation of the ionisation density dependence of the glow curve characteristics of LIF:MG,TI (TLD-100).

The dependence of the shape of the glow curve of LiF:Mg,Ti (TLD-100) on ionisation density was investigated using irradiation with (90)Sr/(90)Y beta rays, 60 and 250 kVp X rays, various heavy-charged particles and 0.2 and 14 MeV neutrons. Special attention is focused on the properties of high-temperature thermoluminescence; specifically, the behaviour of the high-temperature ratio (HTR) of Peak...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001