چکیده

Carbomer gel was prepared with 300mM D-sorbitol (Sigma-Aldrich, St. Louis, MO) and 10mM HEPES free acid (Sigma-Aldrich, St. Louis, MO) in heated distilled water. A gelling agent, carbomer 940 (Snowdrift Farm, Tucson, AZ), was added to the heated sorbitol solution under constant stirring, to reach a concentration of 0.3%, based on a weight percent. Once the carbomer was completely dissolved in the solution, pH was adjusted by drop-wise addition of triethanolamine to 7.2-7.4. The gel was stored in a sealed container at 4°C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short communication: Subcellular motion compensation for minimally invasive microscopy, in vivo: evidence for oxygen gradients in resting muscle.

RATIONALE In vivo microscopy seeks to observe dynamic subcellular processes in a physiologically relevant context. A primary limitation of optical microscopy in vivo is tissue motion, which prevents physiological time course observations or image averaging. OBJECTIVE To develop and demonstrate motion compensation methods that can automatically track image planes within biological tissues, inc...

متن کامل

Oxygen gradients in the microcirculation.

As arterialized blood transits from the central circulation to the periphery, oxygen exits through the vessel walls driven by radial oxygen gradients that extend from the red blood cell column, through the plasma, the vessel wall, and the parenchymal tissue. This exit determines a longitudinal gradient of blood oxygen saturation whose extent is inversely related to the level of metabolic activi...

متن کامل

Dense 3D Depth Recovery for Soft Tissue Deformation During Robotically Assisted Laparoscopic Surgery

Recovering tissue deformation during robotic assisted minimally invasive surgery is an important step towards motion compensation and stabilization. This paper presents a practical strategy for dense 3D depth recovery and temporal motion tracking for deformable surfaces. The method combines image rectification with constrained disparity registration for reliable depth estimation. The accuracy a...

متن کامل

Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures

Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...

متن کامل

Minimally Invasive Repair of Acute Achilles Tendon Rupture Using Gift Box Technique

Background: This study aimed to introduce a modified technique for minimally invasive Achilles tendon (AT) rupture repairusing gift box sutures. The preliminary clinical and functional outcomes were investigated among a number of patients.Methods: In a consecutive case series study, 24 patients with acute AT rupture underwent modified minimally invasiveAT repair using two mini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010