Considerations of marrow cellularity in 3-dimensional dosimetric models of the trabecular skeleton.

نویسندگان

  • Wesley E Bolch
  • Phillip W Patton
  • Didier A Rajon
  • Amish P Shah
  • Derek W Jokisch
  • Benjamin A Inglis
چکیده

UNLABELLED Dose assessment to active bone marrow is a critical feature of radionuclide therapy treatment planning. Skeletal dosimetry models currently used to assign radionuclide S values for clinical marrow dose assessment are based on bone and marrow cavity chord-length distributions. Accordingly, these models cannot explicitly consider energy loss to inactive marrow (adipose tissue) during particle transport across the trabecular marrow space (TMS). One method to account for this energy loss is to uniformly scale the resulting TMS absorbed fractions by reference values of site-specific marrow cellularity. In doing so, however, the resulting absorbed fractions for self-irradiation of the trabecular active marrow (TAM) do not converge to unity at low electron source energies. This study attempts to address this issue by using nuclear magnetic resonance microscopy images of trabecular bone to define 3-dimensional (3D) dosimetric models in which explicit spatial distributions of adipose tissue are introduced. METHODS Cadaveric sources of trabecular bone were taken from both the femoral heads and humeral epiphyses of a 51-y-old male subject. The bone sites were sectioned and subsequently imaged at a proton resonance frequency of 200 MHz (4.7 T) using a 3D spin-echo pulse sequence. After image segmentation, voxel clusters of adipocytes were inserted interior to the marrow cavities of the binary images, which were then coupled to the EGS4 radiation transport code for simulation of active marrow electron sources. RESULTS Absorbed fractions for self-irradiation of the TAM were tabulated for both skeletal sites. Substantial variations in the absorbed fraction to active marrow are seen with changes in marrow cellularity, particularly in the energy range of 100-500 keV. These variations are seen to be more dramatic in the humeral epiphysis (larger marrow volume fraction) than in the femoral head. CONCLUSION Results from electron transport in 3D models of the trabecular skeleton indicate that current methods to account for marrow cellularity in chord-based models are incomplete. At 10 keV, for example, the Eckerman and Stabin model underestimates the self-absorbed fraction to active marrow by 75%. At 1 MeV, the model of Bouchet et al. overestimates this same value by 40%. In the energy range of 20-200 keV, neither model accurately predicts energy loss to the active bone marrow. Thus, it is proposed that future extensions of skeletal dosimetry models use 3D transport techniques in which explicit delineation of active and inactive marrow is feasible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Topological Relationship Between One-Dimensional Box Model and Randić Indices in Linear Simple Conjugated Polyenes

The alternative double bonds and conjugation in the polyene compounds are one of the main properties in these compounds. Each carbon-carbon bonds in a polyene compound along the chain has appreciable double-bond character. The p-electrons are therefore not localized but are relatively free to move throughout the entire carbon skeleton as an one-dimensional box. The skeleton be considered as a r...

متن کامل

Chord distributions across 3D digital images of a human thoracic vertebra.

Radiation dose estimates to the trabecular region of the skeleton are of primary importance due to recent advancements in nuclear medicine. Establishing methods for accurately calculating dose in these regions is difficult due to the complex microstructure of this anatomic site and the typical ranges of beta-particles in both bone and marrow tissues. At the present time, models of skeletal dosi...

متن کامل

Regeneration of blood-forming organs after autologous leukocyte transfusion in lethally irradiated dogs. II. Distribution and cellularity of the marrow in irradiated and transfused animals.

Dogs were given transfusions of cryopreserved autologous mononuclear blood leukocytes after 1200 roentgens (R) (midline dose) whole-body x-irradiation. Bone marrow repopulation was studied by means of histomorphological methods at days 9 and 10 after transfusion of an average of 3 X 10(9), 7 X 10(9), 13 X 10(9), and 31 X 10(9) cells. The return of marrow cellularity to normal values was related...

متن کامل

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Morphologic Variation in the Osteopetrotic Op/Op Mouse Skeleton

SUMMARY This study is designed to confirm the changes of various bones in the osteopetrotic op/op mouse. The female adult mouse were sonicated in papain solution. After the complete treatment, the bones (Skull, Mandible, Scapula, Humerus, Radius, Ulna, Hip, Femure, Tibia, Atlas, Axis and 5th Lumbar vertebra) were measured three dimensionally using of high quality scale and low power binocular ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2002