Treatment of unstable distal radius fractures with the volar locking plate
نویسندگان
چکیده
BACKGROUND Open reduction and internal fixation using an interlocking plate system has gained popularity for the treatment of dorsally displaced distal radius fractures. PURPOSE To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate. PATIENTS AND METHODS A retrospective review was conducted of patients from one institution using the volar locking plate to treat intra-articular and extra-articular distal radius fractures. Unstable distal radius fractures in 15 patients, comprising 3 men and 12 women with a mean age of 64.4 years (34-76 years), were treated with a volar locking compression plate (Acu-Loc distal radius plate system; Acumed, Oregon, USA) and followed up for a minimum of 1 year. Fractures were classified using the AO classification. Radiographic parameters of preoperative, postoperative, and final follow-up radiographs were compared. The time to initiation of active range of motion was determined. Final follow-up range of motion and complications were reported. RESULTS At final functional assessment, the scores of 5 patients were excellent, 7 patients good, and 3 patients fair according to Cooney's Clinical Scoring Chart. No non-union or infection occurred. Rupture of the flexor pollicis longus tendon occurred in 1 patient. CONCLUSION Treatment of unstable distal radius fractures with a volar locking plate leads to satisfactory results, provided the operative technique is carefully performed to prevent complications.
منابع مشابه
Complications and Plate Removal Surgeries after Performing Volar Plating of Unstable Distal Radius Fractures
Complications have often been reported in the literature after distal radius fractures treated conservatively or operatively [1-3]. Previously, the main indication for volar plating was a volar Barton or Smith fracture, but now volar locking plates are the most commonly used treatment for unstable distal radius fractures and during the last decade this method has become increasingly popular [4]...
متن کاملVolar fixation of dorsally displaced distal radial fracture using locking compression plate.
PURPOSE To evaluate the functional and radiological results of treating unstable fractures of the dorsal distal radius with a volar locking plate. METHODS Dorsally displaced distal radial fractures in 30 patients (11 men and 19 women; mean age, 58.6 years) were fixed by volar locking compression plate and followed up for a minimum of one year. RESULTS At final functional assessment, 24 pati...
متن کاملComparison of volar locking plate and external fixation with K wire augmentation in unstable distal radius fractures
Distal radius fractures are one of the most common injuries and this incidence is likely to increase as the aging population increases. The type of operation and implant is a matter of discussion and randomized trials and meta analyses have failed to recommend the preferred implant. Internal fixation with volar locking plate and external fixation with supplementation with K wire have been succe...
متن کاملDistal radius measurements and efficacy of fixed-angle locking volar plates.
AIM For surgical treatment of unstable distal radius fractures, fixed-angled locking volar plate fixation is becoming popular nowadays because of some advantages over other surgical techniques. In this article, we discuss the fitting of fixed-angle locking volar plates to the distal radius in relation to the changes in the distal radial angles. MATERIALS AND METHODS First, we took conventiona...
متن کاملEvaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate.
PURPOSE To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. METHODS A simulated, unstable, extra- articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator [Mirza Cross Pin Fixator (CPX)...
متن کامل