Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report
نویسندگان
چکیده
BACKGROUND Distal radius fracture is the most common fracture of the upper extremity, and approximately 60,000 distal radius fractures occur annually in Korea. Internal fixation with an anatomical volar locking plate is widely used in the treatment of unstable distal radius fractures. However, most of the currently used distal radius anatomical plate systems were designed based on the anatomical characteristics of Western populations. Recently, the Korean-type distal radius anatomical volar plate (K-DRAVP) system was designed and developed based on the anatomical characteristics of the distal radius of Koreans. The purpose of this study was to evaluate the preliminary results of the new K-DRAVP system, and to compare its radiologic and functional results with those of the other systems. METHODS From March 2012 to October 2012, 46 patients with acute distal radius fractures who were treated with the K-DRAVP system at three hospitals were enrolled in this study. Standard posteroanterior and lateral radiographs were obtained to assess fracture healing, and three radiographic parameters (volar tilt, radial inclination, and radial length) were assessed to evaluate radiographic outcomes. The range of motion and grip strength, the Gartland and Werley scoring system, and the disabilities of the arm, shoulder and hand (DASH) questionnaire were used to assess clinical and functional outcomes. RESULTS All radiologic parameters were restored to normal values, and maintained without any loosening or collapse until the time of final follow-up. Grip strength was restored to 84% of the value for the unaffected side. The mean range of motion of the wrist at final follow-up was restored to 77%-95% of the value for the unaffected side. According to the Gartland and Werley scoring system, there were 16 excellent, 26 good, and 4 fair results. The mean DASH score was 8.4 points. There were no complications after surgery. CONCLUSIONS The newly developed K-DRAVP system could be used to restore and maintain good anatomical parameters, and provide good clinical outcomes with low complication rates. This system is a promising surgical option for the treatment of distal radius fractures in the Korean population.
منابع مشابه
Various volar shapes of the distal radius and its implications on volar plate osteosynthesis
Volar plate fi xation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variati...
متن کاملDistal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...
متن کاملDifficulty in Fixation of the Volar Lunate Facet Fragment in Distal Radius Fracture
Recent reports suggest the presence of a rare fracture type for which reduction and fixation cannot be achieved with volar locking plate (VLP). In particular, it is difficult to achieve reduction and fixation with volar lunate facet (VLF) fragments present on the volar ulnar aspect of the lunate facet, because of the anatomical structure and biomechanics in this region. Herein, we report two ch...
متن کاملVolar plate position and flexor tendon rupture following distal radius fracture fixation.
PURPOSE To determine whether there were differences between plate position in patients who had postoperative flexor tendon ruptures following volar plate fixation of distal radius fractures and those who did not. METHODS Three blinded reviewers measured the volar plate prominence and position on the lateral radiographs of 8 patients treated for flexor tendon ruptures and 17 matched control pa...
متن کاملAnatomy of the distal volar radius and its implications on volar plate osteosynthesis
Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variatio...
متن کامل