Quantification of myocardial perfusion with spiral pulse sequences

نویسندگان

  • Yang Yang
  • Sujith Kuruvilla
  • Craig H Meyer
  • Christopher M Kramer
  • Michael Salerno
چکیده

Background The quest to quantify myocardial perfusion has been largely motivated by the desire to obtain quantitative, observer-independent, and reproducible measures of myocardial perfusion. Spiral pulse sequences have multiple advantages for myocardial perfusion imaging including high acquisition efficiency, high signal to noise (SNR) and robustness to motion. We have developed a spiral pulse sequence with an integrated single-shot arterial input function (AIF) capable of performing absolute quantification of myocardial perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Motion-corrected compressed-sensing enables robust spiral first-pass perfusion imaging with whole heart coverage

Background First-pass perfusion imaging using CMR is an important tool for diagnosing coronary artery disease (CAD), but most clinical techniques are limited in their spatial coverage. While compressed-sensing (CS) holds promise for highly accelerated perfusion spiral imaging, CS techniques suffer from blurring artifacts in the setting of respiratory motion. Spiral pulse sequences have multiple...

متن کامل

Adenosine stress CMR with spiral pulse sequences accurately detect CAD

Background Adenosine stress perfusion imaging with CMR has been limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. We have previously demonstrated that spiral pulse sequences can produce high quality first-pass perfusion images.[1] We have further improved this spiral technique using high-resolution variable density spiral trajectories and a no...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013