Measurement of Aortic Pulse Wave Velocity With a Connected Bathroom Scale
نویسندگان
چکیده
BACKGROUND Measurement of arterial stiffness should be more available. Our aim was to show that aortic pulse wave velocity can be reliably measured with a bathroom scale combining the principles of ballistocardiography (BCG) and impedance plethysmography on a single foot. METHOD The calibration of the bathroom scale was conducted on a group of 106 individuals. The aortic pulse wave velocity was measured with the SphygmoCor in the supine position. Three consecutive measurements were then performed on the Withings scale in the standing position. This aorta-leg pulse transit time (alPTT) was then converted into a velocity with the additional input of the height of the person. Agreement between the SphygmoCor and the bathroom scale so calibrated is assessed on a separate group of 86 individuals, following the same protocol. RESULTS The bias is 0.25 m·s-1 and the SE 1.39 m·s-1. This agreement with Sphygmocor is "acceptable" according to the ARTERY classification. The alPTT correlated well with cfPTT with (Spearman) R = 0.73 in pooled population (cal 0.79, val 0.66). The aorta-leg pulse wave velocity correlated with carotid-femoral pulse wave velocity with R = 0.76 (cal 0.80, val 0.70). CONCLUSION Estimation of the aortic pulse wave velocity is feasible with a bathroom scale. Further investigations are needed to improve the repeatability of measurements and to test their accuracy in different populations and conditions.
منابع مشابه
[op.lb03.04] First in Man Measurement of Arterial Stiffness Using a Connected Bathroom Scale: Calibration against Sphygmocor.
OBJECTIVE Measurement of arterial stiffness (AS) is still hampered by the technical skill necessary to obtain reliable measurements. It is generally considered that AS is not prone to self-measurement. We developed a non-invasive technique to assess AS from a connected bathroom scale, based on ballistocardiography (BCG) and impedance plethysmography (IPG).(Figure is included in full-text articl...
متن کاملInternational Journal of Pharma and Bio Sciences NOVEL METHOD FOR MEASUREMENT OF AORTIC PULSE WAVE VELOCITY BY PHOTOELECTRIC PULSE TRANSDUCER COUPLED WITH ECG: A PILOT STUDY SATISH.G.PATIL*, G.B.DHANAKSHIRUR, MANJUNATHA R AITHALA AND SANTOSH PALEKAR
Arterial stiffness is considered an increasingly important biomarker in the evaluation of cardiovascular risk. The gold standard for assessment of arterial stiffness is measurement of aortic pulse wave velocity (PWV). The aim of the present study is to establish a new method for measurement of aortic PWV by using Photoelectric technique coupled with ECG. We studied 36 healthy male subjects betw...
متن کاملAcute effects of ultrafiltration on aortic mechanical properties determined by measurement of pulse wave velocity and pulse propagation time in hemodialysis patients
OBJECTIVE The effects of acute hemodialysis session on pulse wave velocity are conflicting. The aim of the current study was to assess the acute effects of ultrafiltration on the aortic mechanical properties using carotid-femoral (aortic) pulse wave velocity and pulse propagation time. METHODS A total of 26 (12 women, 14 men) consecutive patients on maintenance hemodialysis (mean dialysis dur...
متن کاملDetermination of aortic pulse wave velocity from waveform decomposition of the central aortic pressure pulse.
Aortic pulse wave velocity (PWV), calculated from pulse transit time (PTT) using 2 separate pulse recordings over a known distance, is a significant biomarker of cardiovascular risk. This study evaluates a novel method of determining PTT from waveform decomposition of central aortic pressure using a single pulse measurement. Aortic pressure was estimated from a transformed radial pulse and deco...
متن کاملAortic stiffness predicts functional outcome in patients after ischemic stroke.
BACKGROUND AND PURPOSE Increased aortic stiffness (measured by carotid-femoral pulse wave velocity) and central augmentation index have been shown to independently predict cardiovascular events, including stroke. We studied whether pulse wave velocity and central augmentation index predict functional outcome after ischemic stroke. METHODS In a prospective study, we enrolled 99 patients with a...
متن کامل