Effect of downscaling on the linearity range of a calibration curve in spectrofluorimetry
نویسندگان
چکیده
Interest in the microfluidic environment, owing to its unique physical properties, is increasing in much innovative chemical, biological, or medicinal research. The possibility of exploiting and using new phenomena makes the microscale a powerful tool to improve currently used macroscopic methods and approaches. Previously, we reported that an increase in the surface area to volume ratio of a measuring cell could provide a wider linear range for fluorescein (Kwapiszewski et al., Anal. Bioanal. Chem. 403:151-155, 2012). Here, we present a broader study in this field to confirm the assumptions we presented before. We studied fluorophores with a large and a small Stokes shift using a standard cuvette and fabricated microfluidic detection cells having different surface area to volume ratios. We analyzed the effect of different configurations of the detection cell on the measured fluorescence signal. We also took into consideration the effect of concentration on the emission spectrum, and the effect of the surface area to volume ratio on the limit of linearity of the response of the selected fluorophores. We observed that downscaling, leading to an increase in the probability of collisions between molecules and cell walls with no energy transfer, results in an increase in the limit of linearity of the calibration curve of fluorophores. The results obtained suggest that microfluidic systems can be an alternative to the currently used approaches for widening the linearity of a calibration curve. Therefore, microsystems can be useful for studies of optically dense samples and samples that should not be diluted.
منابع مشابه
USE OF ORGANIC SOLVENTS FOR THE ENHANCEMENT AND LIFETIME INCREASING OF LUMINESCENCE IN FLUORIMETRIC APPLICATION BY FLUORESCAMINE
In this study, the fluorogenic efficiency of fluorescamine for spectrofluorimetric analysis of primary amines was investigated. Different mixtures of dichloromethane and other organic solvents were used for evaluation of fluorescence stability and intensity of fluorescamine derivative (Pyrrolinone). Solvents such as acetonitrile (ACN), tetrahydrofuran (THF) and dioxane increase stability an...
متن کاملCoFe2O4 nanoparticles grafted multi-walled carbon nanotubes coupled with surfactant-enhanced spectrofluorimetry for determination of ofloxacin in human plasma
An efficient and simple magnetic solid phase extraction based on the use of CoFe3O4 nanoparticles grafted multi-walled carbon nanotubes (MWCNTs) as adsorbent coupled with surfactant enhanced spectrofluorimetric detection...
متن کاملA Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples
In this study, a new reaction system for quantitative determination of ascorbic acid was introduced. The developed method is based on inhibitory effect of ascorbic acid on the Orange G-bromate system. The change in absorbance was followed spectrophotometrically at 478 nm. The dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investiga...
متن کاملSpiked Calibration Curve: A Valid Method for Simultaneous Analysis of Pesticides in Melon Using Gas Chromatography Mass Spectrometry (GC/MS)
Recently, with increasing public awareness of food safety, developments of some valid and rapidly analytical methods are required for the determination of residual pesticides in crops.This study was conducted on validation of a reliable, accurate and precise method for multi analysis of pesticides residue in melon as a main fruit in Iranian food basket. A reliable, and valid method...
متن کاملUltrasound Assisted Surfactant Enhanced Emulsification Microextraction and Spectrofluorimetry for Determination of Oxadiazon in Agricultural Water Samples
In this work, an environmentally friendly sample pre-treatment method, Ultrasound Assisted Surfactant Enhanced Emulsification Microextraction (UASEME) followed with spectrofluorimetry was performed for determination of oxadiazon residues in water samples. After the determination of the most suitable extraction solvent and its volume, other parameters such as type and concentration of surfac...
متن کامل