An adaptive on-line method for the extraction of the complete fetal electrocardiogram from cutaneous multilead recordings.
نویسندگان
چکیده
The detection of a fetal electrocardiogram (FECG) is described to be a so-called inverse problem. A geometric interpretation of such a problem is presented. It can be solved by determining the weights to be used in one or more weighted sums of measurement signals. A novel method is presented to determine these weights. Theoretical and experimental evidence is given that this method has the following attractive properties. Application of the method results in one or more FECG signals, free of maternal ECG (MECG) which are at the same time maximal with respect to noise. It is shown that one FECG signal does not always suffice to describe the observed electrical heart activity in a set of cutaneous electrodes, equivalently to the adult ECG (see figure 7). It is explained and experimentally verified that the application of three thoracic signals is useful to guarantee the suppression of the MECG. The positions of the abdominal electrodes then determine the obtained FECG to noise ratio, and will have no influence on the degree of MECG suppression (see figure 6). It is expected that a total of about eight measurement signals are sufficient in most cases. The method is simple to apply by medical personnel, and after a transient of about 1 s the signals with the mentioned properties are obtained (see figure 5). Further on, the weights are allowed to change in order to adapt automatically to sudden changes in the measurement signal properties (see figure 6). These may occur e. g. due to fetal movement. Application of the method requires no human interpretation or decision in order to obtain the claimed properties.
منابع مشابه
A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment
Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant.Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a be...
متن کاملINTELLIGENT TECHNIQUE OF CANCELING MATERNAL ECG IN FECG EXTRACTION
In this paper, we propose a technique of artificial intelligence called adaptive neuro fuzzy inference system (ANFIS) for canceling maternal electrocardiogram (MECG) in fetal electrocardiogram extraction (FECG).This technique is used to estimate the MECG present in the abdominal signal of a pregnant woman. The FECG is then extracted by subtracting the estimated MECG from the abdominal signal. P...
متن کاملEstimation of harmonic interference parameters of surface-NMR signal using an adaptive method and residual signal power
Surface nuclear magnetic resonance (surface-NMR) method is a well-known tool for determining the water-bearing layers and subsurface resistivity structure. Harmonic interference is an inevitable interference in surface-NMR measurements. Accurate estimation of harmonic interference parameters (i.e., fundamental frequency, phase and amplitude) leads to better retrieval of power-line harmonics and...
متن کاملRemoving ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique
Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...
متن کاملFetal Electrocardiogram Extraction by Source Subspace Separation Proceedings Ieee Sp / Athos Workshop on Higher-order Statistics Fetal Electrocardiogram Extraction by Source Subspace Separation
A high-precision method is presented for the extraction of the fetal electrocardiogram from multi-channel potential recordings on the mother's skin. First the problem is appropriately formulated in terms of blind source separation, where the sources can have a multi-dimensional nature. As a summary of preceding work it is shown how the fetal electrocardiogram can be reconstructed by means of se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of perinatal medicine
دوره 14 6 شماره
صفحات -
تاریخ انتشار 1986