Increased risk of restenosis after placement of gold-coated stents: results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease.
نویسندگان
چکیده
BACKGROUND Gold is a highly biocompatible material. Experimental evidence suggests that coating the stent with a gold layer may have a beneficial influence. In this randomized trial, we assessed whether gold-coated stents were associated with a better clinical and angiographic outcome after coronary placement. METHODS AND RESULTS Patients with symptomatic coronary artery disease were randomly assigned to receive either a gold-coated Inflow stent (n = 367) or an uncoated Inflow stainless steel stent (n = 364) of identical design. Follow-up angiography was routinely performed at 6 months. The primary end point of the study was the occurrence of any adverse clinical event (death, myocardial infarction, or target-vessel revascularization) during the first year after stenting. At 30 days, there was no significant difference in the combined incidence of adverse events, with 7.9% in the gold-stent group versus 5.8% in the steel-stent group (P = 0.25). The incidence of angiographic restenosis (> or =50% diameter stenosis) was 49.7% in the gold-stent group and 38.1% in the steel-stent group (P = 0.003). One-year survival free of myocardial infarction was 88.6% in the gold-stent group and 91.8% in the steel-stent group (P = 0.14). One-year event-free survival was significantly less favorable in the gold-stent group (62.9% versus 73.9% in the steel-stent group; P = 0.001). CONCLUSIONS Coating steel stents with gold had no significant influence on the thrombotic events observed during the first 30 days after the intervention. However, gold-coated stents were associated with a considerable increase in the risk of restenosis over the first year after stenting.
منابع مشابه
Randomized comparative study of diamond-like carbon coated stainless steel stent versus uncoated stent implantation in patients with coronary artery disease.
OBJECTIVE To compare restenosis and major cardiac event rates at one and six months after DLC-coated stent implantation with those of uncoated stents. METHODS Randomized, prospective, comparative study of 180 patients with coronary insufficiency undergoing DLC coated stent (Phytis) or uncoated stent (Penta) implantation, from January, 2003 to July, 2004. Inclusion criteria were: de novo lesio...
متن کاملCoated stents to prevent restenosis in coronary heart disease
BACKGROUND In-stent-restenosis (ISR) is considered to be an essential limiting factor of stenting in coronary heart disease (CHD). The development of coated stents has raised expectations on substantial lowering restenosis after stenting with decreasing the rate of restenosis and a reduction in the rate of clinical events. OBJECTIVES The present analysis addresses the questions on medical eff...
متن کامل'Fused-Gold' vs. 'Bare' stainless steel NIRflex stents of the same geometric design in diseased native coronary arteries. Long-term results from the NIR TOP Study.
OBJECTIVES We evaluated the long-term clinical and angiographic results of 'fused-gold' (NIRFlex Royal) and 'bare' (NIRFlex) stainless steel stents in patients undergoing percutaneous coronary intervention (PCI). BACKGROUND Recent studies have shown high clinical and angiographic restenosis rates following the intracoronary implantation of 'gold-coated' stainless steel stents. The new 'fused-...
متن کاملGold-coated NIR stents in porcine coronary arteries.
BACKGROUND As endovascular stents are altered to add functionality, eg, by adding radiopaque coatings, biocompatibility may suffer. METHODS AND RESULTS We examined the vascular response in porcine coronary arteries to stainless steel gold-coated NIR stents (7-cell, Medinol, Inc). Stents, 9 and 16 mm in length, were left bare or coated with a 7-microm layer of gold. Physical and material effec...
متن کاملEffects of gold coating of coronary stents on neointimal proliferation following stent implantation.
Experimental studies suggest a reduced neointimal tissue proliferation in vascular stainless steel stents coated with gold. This prospective multicenter trial evaluated the impact of gold coating on neointimal tissue proliferation in patients undergoing elective stent implantation. The primary end point was the in-stent tissue proliferation measured by intravascular ultrasound at 6 months compa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 101 21 شماره
صفحات -
تاریخ انتشار 2000