Implementation of continuous 3D whole-body PET scanning using on-the-fly Fourier rebinning.
نویسندگان
چکیده
The continuous scanning mode in three-dimensional (3D) whole-body PET studies has the advantage of axial sensitivity uniformity over the majority of the axial FOV. However, this scan mode requires large data handling compared to conventional discrete scans. In this work, we have implemented and evaluated a new continuous 3D scan method using 'on-the-fly' Fourier rebinning. In this method, sinograms for the pair of rings are added in real-time into the sinograms of the incremented ring pairs by moving the bed axially one detector width at a time. For an N-ring scanner, 2N--1 sinograms are transferred to a host computer at each bed position and rebinned into direct two-dimensional (2D) sinograms using Fourier rebinning. Phantom and human studies showed that the axial image uniformity is achieved without degrading the axial resolution. This method can minimize the time for off-line data processing and makes the continuous 3D scan more feasible in clinical whole-body studies.
منابع مشابه
Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST
Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...
متن کاملClinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.
We present the results of utilizing aligned anatomical information from CT images to locally adjust image smoothness during the reconstruction of three-dimensional (3D) whole-body positron emission tomography (PET) data. The ability of whole-body PET imaging to detect malignant neoplasms is becoming widely recognized. Potentially useful, however, is the role of whole-body PET in quantitative es...
متن کاملApproximate Fourier Rebinning Algorithms for the Solution of the Data Truncation Problem in 3d Pet
This paper presents an extended three-dimensional (3D) exact rebinning formula in the Fourier space that leads to an iterative reprojection algorithm (iterative FOREPROJ), which enables the estimation of unmeasured oblique projection data on the basis of the whole set of measured data. In first approximation, this analytical formula also leads to an extended Fourier rebinning equation that is t...
متن کاملIterative Reconstruction Methods for High- Throughput PET Scanners
Iterative reconstructions for clinical PET must run fast. We describe a clinical processing method based on sinogram rebinning, Fourier rebinning for the 3D to 2D data reduction, and iterative reconstruction using the attenuation-weighted OSEM method with a projector based on a gaussian pixel model. When this approach is used, multi-bed clinical oncology scans can be ready for diagnosis within ...
متن کاملThe 8th International Meeting on Fully Three-dimensional Image Reconstruction in Radiology and Nuclear Medicine Salt Lake
This paper explores fast reconstruction strategies for 3D time-of-flight (TOF) PET, based on 2D data rebinning. We introduce TOF-FORE, an approximate rebinning algorithm obtained by extending the Fourier rebinning method for non-TOF data. In addition, we identify two partial differential equations that must be satisfied by consistent 3D TOF data, and use them to derive exact rebinning algorithm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 47 15 شماره
صفحات -
تاریخ انتشار 2002