iELVis: An open source MATLAB toolbox for localizing and visualizing human intracranial electrode data.
نویسندگان
چکیده
BACKGROUND Intracranial electrical recordings (iEEG) and brain stimulation (iEBS) are invaluable human neuroscience methodologies. However, the value of such data is often unrealized as many laboratories lack tools for localizing electrodes relative to anatomy. To remedy this, we have developed a MATLAB toolbox for intracranial electrode localization and visualization, iELVis. NEW METHOD: iELVis uses existing tools (BioImage Suite, FSL, and FreeSurfer) for preimplant magnetic resonance imaging (MRI) segmentation, neuroimaging coregistration, and manual identification of electrodes in postimplant neuroimaging. Subsequently, iELVis implements methods for correcting electrode locations for postimplant brain shift with millimeter-scale accuracy and provides interactive visualization on 3D surfaces or in 2D slices with optional functional neuroimaging overlays. iELVis also localizes electrodes relative to FreeSurfer-based atlases and can combine data across subjects via the FreeSurfer average brain. RESULTS It takes 30-60min of user time and 12-24h of computer time to localize and visualize electrodes from one brain. We demonstrate iELVis's functionality by showing that three methods for mapping primary hand somatosensory cortex (iEEG, iEBS, and functional MRI) provide highly concordant results. COMPARISON WITH EXISTING METHODS: iELVis is the first public software for electrode localization that corrects for brain shift, maps electrodes to an average brain, and supports neuroimaging overlays. Moreover, its interactive visualizations are powerful and its tutorial material is extensive. CONCLUSIONS iELVis promises to speed the progress and enhance the robustness of intracranial electrode research. The software and extensive tutorial materials are freely available as part of the EpiSurg software project: https://github.com/episurg/episurg.
منابع مشابه
iElectrodes: A Comprehensive Open-Source Toolbox for Depth and Subdural Grid Electrode Localization
The localization of intracranial electrodes is a fundamental step in the analysis of invasive electroencephalography (EEG) recordings in research and clinical practice. The conclusions reached from the analysis of these recordings rely on the accuracy of electrode localization in relationship to brain anatomy. However, currently available techniques for localizing electrodes from magnetic reson...
متن کاملMocap Toolbox – a Matlab Toolbox for Computational Analysis of Movement Data
The MoCap Toolbox is a set of functions written in Matlab for analyzing and visualizing motion capture data. It is aimed at investigating music-related movement, but can be beneficial for other research areas as well. Since the toolbox code is available as open source, users can freely adapt the functions according to their needs. Users can also make use of the additional functionality that Mat...
متن کاملMEA-Tools: an open source toolbox for the analysis of multi-electrode data with MATLAB.
Recent advances in electrophysiological techniques have created new tools for the acquisition and storage of neuronal activity recorded simultaneously with numerous electrodes. These techniques support the analysis of the function as well as the structure of individual electrogenic cells in the context of surrounding neuronal or cardiac network. Commercially available tools for the analysis of ...
متن کاملMicroarray Data Analysis Toolbox (MDAT): for normalization, adjustment and analysis of gene expression data
SUMMARY We introduce a novel Matlab toolbox for microarray data analysis. This toolbox uses normalization based upon a normally distributed background and differential gene expression based on five statistical measures. The objects in this toolbox are open source and can be implemented to suit your application. AVAILABILITY MDAT v1.0 is a Matlab toolbox and requires Matlab to run. MDAT is fre...
متن کاملMATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG
Reference electrode standardization technique (REST) has been increasingly acknowledged and applied as a re-reference technique to transform an actual multi-channels recordings to approximately zero reference ones in electroencephalography/event-related potentials (EEG/ERPs) community around the world in recent years. However, a more easy-to-use toolbox for re-referencing scalp EEG data to zero...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neuroscience methods
دوره 281 شماره
صفحات -
تاریخ انتشار 2017