Evaluation of an automated sample preparation protocol for quantitative detection of hepatitis C virus RNA.
نویسندگان
چکیده
The COBAS AMPLIPREP instrument for automated sample preparation has recently been introduced. In this study, the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test, which includes this new molecular device, was evaluated and compared to the COBAS AMPLICOR HCV MONITOR test, which includes a manual extraction protocol. Interassay and intra-assay variation, precision, and linearity were determined, and a total of 130 clinical specimens were investigated. For determination of interassay variation, coefficients of variation were found to be between 9 and 59% for the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and between 13 and 69% for the COBAS AMPLICOR HCV MONITOR test. For determination of intra-assay variation, coefficients of variation were found to be between 7 and 13% for the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and between 8 and 16% for the COBAS AMPLICOR HCV MONITOR test. When precision of the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test was tested, all results were found to be within +/-0.5 log of the expected results. Determination of linearity resulted in a quasilinear curve over 3 logs. When clinical samples were tested with the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and compared with the COBAS AMPLICOR HCV MONITOR test, all results were found within +/-0.5 log. In conclusion, the assay, which included the new molecular device, proved to be suitable for the routine molecular laboratory. It was found to be laborsaving and easy to handle.
منابع مشابه
O-2: Prospective Evaluation of the ThreatRelated to the Use of Seminal Fractions fromHepatitis C Virus-Infected Men in Assisted ReproductiveTechniques
Background: The risk of hepatitis C virus (HCV) transmission during assisted reproductive techniques (ARTs) is still disputed and no report concerning its prospective evaluation is available. The aim of this 4-year follow-up multicentre study that enrolled 86 HCV-serodiscordant couples was to determine whether a sperm-processing method was able to reduce levels of HCV in semen and the risk of H...
متن کاملMolecular Detection of HGV RNA in Chronic Hepatitis Patients from Afzalipoor General Hospital in Kerman, Iran
Background and Aims: Viral hepatitis is a global health problem with a high mortality rate. Recently, a new Flavi-like virus, provisionally named hepatitis G virus (HGV), has been described. HGV does not induce an immune response that is consistently detectable by using recombinant proteins from prokaryotic expression, therefore studies have been conducted by using polymerase chain reaction (...
متن کاملDetection and Genotyping of Hepatitis D Virus from HBsAg Positive Patients in Iran Using RT-PCR
Hepatitis Delta virus (HDV) is a degenerate RNA virus or virusoid and a satellite of Hepatitis B virus (HBV). Three distinct genotypes are described for HDV; genotype I is distributed worldwide but other genotypes appear to be more restricted geographically. In the present study, an RT-nested PCR method was set up to detect delta infection from serum samples. Moreover, the target amplified sequ...
متن کاملMolecular detection of hepatitis delta virus in blood donors with RT-PCR
Abstract Background and Objective: Hepatitis delta virus is an imperfect virus with RNA and its activity depends on the presence of hepatitis B virus. This virus can lead to acute and chronic diseases in the liver. This study aimed to detect the hepatitis delta virus in blood donors with positive Hepatitis B Surface Antigens (HBsAg). Material and Methods: In this Study, 350 serum sa...
متن کاملتعیین کمی بار ویروسی هپاتیت C با استفاده از روش Real-Time PCR In-House در بیماران آلوده به هپاتیت C در شهرستان خرم آباد
Background : Molecular diagnostic methods are among major tools in management of hepatitis C virus (HCV) in infected patients. Many studies have shown that viral load is associated with stage of infection and response to treatment. Therefore, the evaluation and quantification of viral load is very important. The goal of this study is implementation of inexpensive, yet accurate method for quanti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 40 4 شماره
صفحات -
تاریخ انتشار 2002