Effect of flow split on separation and stagnation in a model vascular bifurcation.

نویسندگان

  • F W LoGerfo
  • H M Crawshaw
  • M Nowak
  • E Serrallach
  • W C Quist
  • C R Valeri
چکیده

This is a study of the flow disturbance in a plastic model of an asymmetric vascular bifurcation. A sidearm was attached to the mainlimb at an angle of 15 degrees to the inlet flow axis. Water at steady flow was used and flow patterns were demonstrated by a dye injection technique. The proportion of inlet flow (Qi) exiting from the sidearm (Qs) was varied and flow patterns were recorded photographically. A laser Doppler anemometer (LDA) was used to measure near-wall velocity. At a physiologic Reynolds' number of 500, no flow disturbance occurred in the mainlimb when the sidearm was completely occluded. When the fraction of flow exiting from the sidearm (Qs/Qi) reached 0.19, a region of boundary layer separation developed along the wall of the mainlimb opposite the flow divider. This region of nearly static fluid spread circumferentially around the mainlimb as Qs/Qi increased. Near-wall velocity within the separation decreased and became negative when Qs/Qi = 0.31. When Qs/Qi reached 0.38, the separation enveloped the wall of the entire bifurcation with a shell of slowly moving fluid. At the same time, the rapidly moving mainstream impinged directly on the flow divider. There is a similarity between the region of separation seen in this model and the site of formation of atherosclerotic plaque at the carotid bifurcation. Separation may contribute to atherogenesis by creating a region of low wall shear at bifurcations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of bilayer flexibility and medium viscosity on separation of liposomes upon stagnation

Liposomes are widely used as drug delivery systems in different forms including osmotic pumps, infusion and IV injection. In spite of these, there is no data available about their behavior under convective flow (e.g. infusion or osmotic pumps) and upon stagnation in such drug delivery systems. As a part of a series of investigations in this area, the present study investigates the effects of vi...

متن کامل

Effect of charge on separation of liposomes upon stagnation

Abstract Liposomes are used widely as drug delivery systems in different forms including nanosuspensions, osmotic pumps, infusion pumps and IV injections. Some of these systems (e.g. infusion or osmotic pumps) might stay stagnant for a long time during or before administration, and therefore, might face phase separation. In spite of these, there is no data available about the behavior of lipos...

متن کامل

Effect of charge on separation of liposomes upon stagnation

Abstract Liposomes are used widely as drug delivery systems in different forms including nanosuspensions, osmotic pumps, infusion pumps and IV injections. Some of these systems (e.g. infusion or osmotic pumps) might stay stagnant for a long time during or before administration, and therefore, might face phase separation. In spite of these, there is no data available about the behavior of lipos...

متن کامل

Effects of Brownian motion and Thermophoresis on MHD Mixed Convection Stagnation-point Flow of a Nanofluid Toward a Stretching Vertical Sheet in Porous Medium

This article deals with the study of the two-dimensional mixed convection magnetohydrodynamic (MHD) boundary layer of stagnation-point flow over a stretching vertical plate in porous medium filled with a nanofluid. The model used for the nanofluid incorporates the effects of Brownian motion and thermophoresis in the presence of thermal radiation. The skin-friction coefficient, Nusselt number an...

متن کامل

Numerical and Experimental Analysis of the Effect of Flow Discharge Ratio on Flow Separation at 45 Degree Open End Water Intake

Flow separation at water intake is the main cause of head loss and flow discharge reduction. &#10As a result, study of shape and size of separation is very essential when designing an optimum water intake. Water intake is normally built with a 90 degree angle to the main channel flow direction. However, the flow structure in this type of water intake consists of large separation size along wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 12 5  شماره 

صفحات  -

تاریخ انتشار 1981