An experiment has been performed to demonstrate the feasibility of proton computed tomography. The proton energy loss was used to measure the projections of the relative stopping power of the phantom. High quality reconstructions were obtained from scans of 19cm and 30cm diameter performance phantoms. Comparison with reconstructions from an EM1 CT-5005 x-ray scanner showed the proton technique is more dose efficient by a large factor.
منابع مشابه
Initial studies on proton computed tomography using a silicon strip detector telescope
We report initial results of a feasibility study of Proton Computed Tomography and Proton Transmission Radiography for applications in proton therapy treatment planning and patient positioning. The aim of the study is to explore experimentally if PCT, which is based on the measurement of the specific energy loss of protons traversing tissues of different density, may be preferred to X-ray Compu...
متن کاملDensity resolution of proton computed tomography.
Conformal proton radiation therapy requires accurate prediction of the Bragg peak position. Protons may be more suitable than conventional x-rays for this task since the relative electron density distribution can be measured directly with proton computed tomography (CT). However, proton CT has its own limitations, which need to be carefully studied before this technique can be introduced into r...
متن کاملProton energy and scattering angle radiographs to improve proton treatment planning : a Monte Carlo study
The novel proton radiography imaging technique has a large potential to be used in direct measurement of the proton energy loss (proton stopping power, PSP) in various tissues in the patient. The uncertainty of PSPs, currently obtained from translation of X-ray Computed Tomography (xCT) images, should be minimized from 3–5% or higher to less than 1%, to make the treatment plan with proton beams...
متن کاملProton energy and scattering angle radiographs to improve proton treatment planning: a Monte Carlo study
The novel proton radiography imaging technique has a large potential to be used in direct measurement of the proton energy loss (proton stopping power, PSP) in various tissues in the patient. The uncertainty of PSPs, currently obtained from translation of X-ray Computed Tomography (xCT) images, should be minimized from 3–5% or higher to less than 1%, to make the treatment plan with proton beams...
متن کاملDevelopment of Proton Computed Tomography for Applications in Proton Therapy
Determination of the Bragg peak position in proton therapy requires accurate knowledge of the electron density and ratio of effective atomic number and mass (Z/A) of the body tissues traversed. While the Z/A ratio is fairly constant for human tissues, the density of tissues varies significantly. One possibility to obtain accurate electron density information of tissues is to use protons of suff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 26 6 شماره
صفحات -
تاریخ انتشار 1981