Safe and Simplified Salvage Technique for Exposed Implantable Cardiac Electronic Devices under Local Anesthesia
نویسندگان
چکیده
BACKGROUND Skin erosion is a dire complication of implantable cardiac pacemakers and defibrillators. Classical treatments involve removal of the entire generator and lead systems, however, these may result in fatal complications. In this study, we present our experience with a simplified salvage technique for exposed implantable cardiac electronic devices (ICEDs) without removing the implanted device, in an attempt to reduce the risks and complication rates associated with this condition. METHODS The records of 10 patients who experienced direct ICED exposure between January 2012 and December 2015 were retrospectively reviewed. The following surgical procedure was performed in all patients: removal of skin erosion and capsule, creation of a new pocket at least 1.0-1.5 cm inferior to its original position, migration of the ICED to the new pocket, and insertion of closed-suction drainage. Patients with gross local sepsis or septicemia were excluded from this study. RESULTS Seven patients had cardiac pacemakers and the other 3 had implantable cardiac defibrillators. The time from primary ICED placement to exposure ranged from 0.3 to 151 months (mean, 29 months. Postoperative follow-up in this series ranged from 8 to 31 months (mean follow-up, 22 months). Among the 10 patients, none presented with any signs of overt infection or cutaneous lesions, except 1 patient with hematoma on postoperative day 5. The hematoma was successfully treated by surgical removal and repositioning of the closed-suction drainage. CONCLUSIONS Based on our experience, salvage of exposed ICEDs is possible without removing the device in selected patients.
منابع مشابه
Treatment of Infected Cardiac Implantable Electronic Devices.
With their rising benefits, cardiac implantable electronic devices (CIEDs) such as pacemakers and left ventricular assist devices (LVADs) have witnessed a sharp rise in use over the past 50 years. As indications for use broaden, so too does their widespread employment with its attendant rise of CIED infections. Such large numbers of infections have inspired various algorithms mandating treatmen...
متن کاملExposed Subcutaneous Implantable Devices: An Operative Protocol for Management and Salvage
BACKGROUND Implantable venous and electrical devices are prone to exposure and infection. Indications for management are controversial, but-especially if infected-exposed devices are often removed and an additional operation is needed to replace the device, causing a delay in chemotherapy and prolonging healing time. We present our protocol for device salvage, on which limited literature is ava...
متن کاملSafety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.
Magnetic resonance imaging (MRI) in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices is sometimes a risky procedure. Thus MRI in these patients should be performed when it is the only examination able to help with the diagnosis. Moreover the diagnostic benefit must outweigh the risks. Coronary artery stents, prosthetic cardiac valves, metal sternal sutur...
متن کاملCardiac implantable electronic device lead extraction using the lead-locking device system: keeping it simple, safe, and inexpensive with mechanical tools and local anesthesia
OBJECTIVE We have previously reported our successful approach for percutaneous cardiac implantable electronic device (CIED) lead extraction using inexpensive tools, which we have continued over the years. Herein we report the results of the systematic use of a unique stylet, the lead-locking device (LLD), which securely locks the entire lead lumen, aided with non-powered telescoping sheaths in ...
متن کاملSimplified local anesthesia technique for external dacryocystorhinostomy without nasal packing: a new technique and pilot study outcome
BACKGROUND The purpose of this paper is to describe a simplified local anesthesia technique for external dacryocystorhinostomy (EXT-DCR). METHODS In this pilot, retrospective, noncomparative, interventional case series, 448 patients (480 eyes) underwent EXT-DCR using a simplified local anesthesia technique. Nasal mucosal anesthesia was achieved using combined application of 6 mL of oxymetazol...
متن کامل