Simultaneous Multislice Diffusion-Weighted Imaging of the Kidney: A Systematic Analysis of Image Quality.
نویسندگان
چکیده
OBJECTIVES The aims of this study were to implement a protocol for simultaneous multislice (SMS) accelerated diffusion-weighted imaging (DWI) of the kidneys and to perform a systematic analysis of image quality of the data sets. MATERIALS AND METHODS Ten healthy subjects and 5 patients with renal masses underwent DWI of the kidney in this prospective institutional review board-approved study on a 3 T magnetic resonance scanner. Simultaneous multislice DWI echo-planar sequences (acceleration factors [AFs] 2 and 3) were compared with conventional echo-planar DWI as reference standard for each acquisition scheme. The following 3 acquisition schemes were applied: comparison A, with increased number of acquisitions at constant scan time; comparison B, with reduction of acquisition time; and comparison C, with increased slice resolution (constant acquisition time, increasing number of slices). Interreader reliability was analyzed by calculating the intraclass correlation coefficient (ICC). Qualitative image quality features were evaluated by 2 independent radiologists on a 5-point Likert scale. Quantification accuracy of the apparent diffusion coefficients (ADCs) and signal-to-noise ratios (SNRs) were assessed by region of interest analysis. Furthermore, lesion conspicuity in the 5 patients was assessed using a 5-point Likert scale by 2 independent radiologists. RESULTS Interreader agreement was substantial with an ICC of 0.68 for the overall image quality and an ICC of 0.73 for the analysis of artifacts. In comparison A, AF2 resulted in increased SNR (P < 0.05) by 21% at stable image quality scores (image quality: P = 0.76, artifacts: P = 0.21). In comparison B, applying AF2, the scan time could be reduced by 46% without significant reduction in qualitative image quality scores (P = 0.059) or SNR (P = 0.126). In comparison C, slice resolution could be improved by 28% using AF2 with stable image quality scores and SNR. In general, AF3 resulted in reduced image quality and SNR. Significantly reduced ADC values were observed for AF3 in comparison C (cortex: P = 0.003; medulla: P = 0.001) compared with the standard echo-planar imaging sequence. The conventional DWI and the SMS DWI with AF2 showed stable lesion conspicuity ([AF1/AF2]: reader 1 [1.8/1.4] and reader 2 [1.8/1.4]). The lesion conspicuity was lower using AF3 (reader 1: 2.2 and reader 2: 1.8). CONCLUSIONS In conclusion, SMS DWI of the kidney is a potential tool to substantially reduce scan time without negative effects on SNR, ADC quantification accuracy, and image quality if an AF2 is used. Although AF3 results in even higher scan time reduction, a negative impact on image quality, SNR, ADC quantification accuracy, and lesion conspicuity must be considered.
منابع مشابه
Scan time reduction for readout‐segmented EPI using simultaneous multislice acceleration: Diffusion‐weighted imaging at 3 and 7 Tesla
PURPOSE Readout-segmented echo-planar imaging (rs-EPI) can provide high quality diffusion data because it is less prone to distortion and blurring artifacts than single-shot echo-planar imaging (ss-EPI), particularly at higher resolution and higher field. Readout segmentation allows shorter echo-spacing and echo train duration, resulting in reduced image distortion and blurring, respectively, i...
متن کاملDynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors
Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...
متن کاملDiagnosis of Meningitis Caused by Pathogenic Microorganisms Using Magnetic Resonance Imaging: A Systematic Review
Introduction: Bacterial meningitis is an acute infectious inflammation of the protective membranes covering the brain. Its early diagnosis is vital because of its high morbidity and mortality. It is mostly diagnosed by a gold standard diagnostic tool i.e. Cerebrospinal Fluid (CSF) analysis. However, it is sometimes difficult and or impossible to do this procedure and an alternative diagnostic t...
متن کاملAccelerated DWI Using Simultaneous Image refocused EPI Optimized for Clinical Imaging
Introduction To reduce imaging times in clinical diffusion imaging, the simultaneous image refocusing (SIR) technique can be utilized to acquire multiple slices in a single readout, thereby shortening the total scan time. With 2 simultaneously refocused echoes, an approximate acceleration factor of 1.5 can be achieved as compared to non-SIR imaging. Multiplexing the slices increases the efficie...
متن کاملApplications of diffusion weighted imaging in detection of radiating pain to lower extremities
Introduction: To examine the hypothesis that diffusion weighted imaging (DWI) in lumbosacral region could reveal sciatic nerve course swelling that lead to lower extremity pain. The aim of present article was to find and evaluate the diffusion weighted coefficients (b-values) for scrutinizing sciatic nerve tract changes in lumbosacral region. Materials and methods: Lumbar area was imaged in 30...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative radiology
دوره 52 3 شماره
صفحات -
تاریخ انتشار 2017