Mid-infrared laser-induced superheating of water and its quantification by an optical temperature probe.

نویسندگان

  • Tobias Brendel
  • Ralf Brinkmann
چکیده

Free-running thulium laser pulses (Cr:Tm:YAG, lambda = 2.01 microm, tp = 300 micros) were applied to a purified, degassed water sample and the resulting temperature rise was investigated by an optical temperature probe. The probe detected water reflectance index changes with temperature and also the onset of vaporization, which was found to occur in a superheat regime, at approximately 230 degrees C. The experimental data were compared with theoretical temperature calculations, and deviations of less than 20 degrees C were stated. The best agreement between theory and experiment was found for temperatures below 180 degrees C, defining by this the method's high accuracy limit. In conclusion, both the optical temperature probe and the presented calculations can help to improve dosimetry in pulsed IR laser applications by precise temperature measurement and prediction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical Opacity of Laser Induced Plasma in Distilled Water with NaCl and TiO2 Nanoparticles Impurities

In this paper, the dynamic behavior of laser induced optical breakdown in impure water was studied by using a pump- probe technique. The plasma was induced by a 1064 nm Nd:YAG laser pulse (with pulse duration ~10 ns) in distilled water with two types of impurities: (I) a solution (highly diluted salt water as a conductor) and (II) a colloidal (TiO2 in colloidal nanoparticle form as a dielectric...

متن کامل

Measuring the deposited energy from a non-ionizing laser beam in water by digital holographic interferometry

Digital Holographic interferometry is a powerful and widely used optical technique for accurate measurement of variations in physical quantities such as density, refractive index, and etc. In this study, an experimental digital holographic interferometry setup was designed and used to measure the amount of energy changes induced by absorption of radiation from a non-ionizing infrared laser beam...

متن کامل

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Noise sources and improved performance of a mid-wave infrared uncooled silicon carbide optical photodetector.

An uncooled photon detector is fabricated for the mid-wave infrared (MWIR) wavelength of 4.21 μm by doping an n-type 4H-SiC substrate with gallium using a laser doping technique. The dopant creates a p-type energy level of 0.3 eV, which is the energy of a photon corresponding to the MWIR wavelength 4.21 μm. This energy level was confirmed by optical absorption spectroscopy. The detection mechan...

متن کامل

Tuning extension of a Difference-Frequency generation up to 100 nm using V-shaped external-cavity for the pump laser

In this research, tunability of a commercial diode laser has extended to about more than ± 11 nm using a V-shaped external-cavity fabricated around the laser. Although under normal condition it can be tuned up to about ± 4 nm just by changing its temperature and injection current. Such modified diode laser has then used in a difference-frequency generation (DFG) experimental setup as pump sourc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 43 9  شماره 

صفحات  -

تاریخ انتشار 2004