Biomechanical evaluation of physeal-sparing fixation methods in tibial eminence fractures.
نویسندگان
چکیده
BACKGROUND Tibial eminence fractures occur most commonly in skeletally immature children. Several techniques using physeal-sparing fracture fixation have been described, but their structural properties have not been evaluated. PURPOSE To determine the strength and resistance to displacement of physeal-sparing techniques used to fix tibial eminence fractures. STUDY DESIGN Controlled laboratory study. METHODS Skeletally immature porcine knees were randomized into 4 treatment groups: (1) ultra-high molecular weight polyethylene suture-suture button (UHMWPE/SB), (2) suture anchor, (3) polydioxanone suture-suture button (PDS/SB), and (4) screw fixation. A prospective analysis of bone mineral density using dual-energy x-ray absorptiometry was performed on all specimens. Fracture fragments were created in a standardized manner and measured for size comparison. After fracture fixation, biomechanical testing was performed with cyclical and load-to-failure protocols by loading the tibia with an anterior shear force. RESULTS In load-to-failure testing, screw fixation had a significantly lower median peak failure load (186.4 N; lower quartile [LQ], 158.4 N; upper quartile [UQ], 232.6 N) than did UHMWPE/SB (465.8 N; LQ, 397.8 N; UQ, 527.8 N), suture anchors (440.5 N; LQ, 323.0 N; UQ, 562.3 N), and PDS/SB (404.3 N; LQ, 385.9 N; UQ, 415.6 N). UHMWPE/SB demonstrated a significantly higher median yield load (465.8 N; LQ, 397.8 N; UQ, 527.8 N) than did PDS/SB (306.7 N; LQ, 271.4, N; UQ, 405.7 N) and screw fixation (179.0 N; LQ, 120.2 N; UQ, 232.5 N). During cyclical testing, screw fixation demonstrated significantly lower percentage survival of specimens (0%) compared with the other groups (UHMWPE/SB, 100%; suture anchor, 78%; PDS/SB, 78%). After 1000 cycles of loading, PDS/SB fixation had significantly more median creep (6.76 mm; LQ, 6.34 mm; UQ, 8.28 mm) than did UHMWPE/SB (4.43 mm; LQ, 3.80 mm; UQ, 4.73 mm) and suture anchor fixation (3.06 mm; LQ, 2.59 mm; UQ, 4.28 mm). The lowest median stiffness was observed in the PDS/SB group (48.6 N/mm; LQ, 45.3 N/mm; UQ, 54.2 N/mm). UHMWPE/SB fixation demonstrated a significantly higher median peak failure load after cyclic testing (469.0 N; LQ, 380.6 N; UQ, 507.2 N) than did PDS/SB (237.7 N; LQ, 197.3 N; UQ, 298.3 N) and screw fixation (132.4 N; LQ, 123.7 N; UQ, 180.9 N). Suture anchor fixation had significantly more variance, as demonstrated by width of interquartile range, in peak failure load, yield load, and creep than did other techniques. CONCLUSION Physeal-sparing fixation of tibial eminence fractures with UHMWPE suture-suture button is biomechanically superior to both PDS suture-suture button and a single screw at the time of surgery and provides more consistent fixation than do suture anchors. CLINICAL RELEVANCE Suture anchors provide inconsistent fixation for tibial eminence fractures.
منابع مشابه
Physeal-sparing tibial eminence fracture fixation with a headless compression screw.
Displaced tibial intercondylar eminence fractures frequently require operative fixation. Surgical techniques for fixation include the use of headed screws or sutures. However, these fractures commonly occur in skeletally immature patients, and current techniques violate the proximal tibial physis to maintain reduction and can result in growth disturbances. The authors present a physeal-sparing ...
متن کاملBiomechanical evaluation of tibial eminence fractures using suture fixation.
This study evaluates the initial fixation strength of tibial eminence fracture repair using 1, 2, 3, and 4 sutures to determine the optimal number of sutures required to adequately secure the avulsed fragment to the tibia. Sixteen skeletally immature porcine knees were stripped of all soft tissues, isolating the femur-anterior cruciate ligament (ACL)-tibia complex. Type III tibial eminence frac...
متن کاملClinical and radiological outcomes of arthroscopically assisted cannulated screw fixation for tibial eminence fracture in children and adolescents
BACKGROUND The purpose of this study was to determine the efficacy and complications of arthroscopically assisted reduction and fixation with cannulated screws for tibial eminence fracture in skeletally immature patients. METHODS This was a retrospective case series study. Forty-eight patients who were skeletally immature at the time of tibial eminence fracture were treated in a tertiary chil...
متن کاملSurgical indications for distal tibial epiphyseal fractures in children.
The goal of this study was to investigate the treatment methods and surgical indications of distal tibial epiphyseal fractures in children. Two hundred eighty-six children with distal tibial epiphyseal fractures were included in the study. Among these patients, 202 were male and 84 were female. Mean age was 11.7 years. A retrospective study on the postoperative long-term complications and relat...
متن کاملOutcomes and second-look arthroscopic evaluation after combined arthroscopic treatment of tibial plateau and tibial eminence avulsion fractures: a 5-year minimal follow-up
BACKGROUND Tibial eminence avulsion fracture often co-occurs with tibial plateau fracture, which leads to difficult concomitant management. The value of simultaneous arthroscopy-assisted treatment continues to be debated despite its theoretical advantages. We describe a simple arthroscopic suture fixation technique and hypothesize that simultaneous treatment is beneficial. METHODS Patients wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of sports medicine
دوره 41 7 شماره
صفحات -
تاریخ انتشار 2013