Cycloplegic and noncycloplegic refractions of Chinese neonatal infants.
نویسندگان
چکیده
PURPOSE To examine Chinese neonatal infants with both cycloplegic and noncycloplegic retinoscopy and to compare the distribution of refractive errors for the two techniques. METHODS Cycloplegic retinoscopy was performed by two experienced pediatric ophthalmologists on 81 neonatal infants randomly selected from a group of 185 neonates who had undergone noncycloplegic retinoscopy. All infants were between 1 day and 6 days of age and were born without incident at full term. RESULTS The mean cycloplegic spherical equivalent (CSE) was highly hyperopic (+3.55 diopters [D] ± 2.39 D). The mean noncycloplegic spherical equivalent (nCSE) was +0.58 D ± 2.32 D. The high reliability of the refractive measurements was demonstrated by high correlations between examiners (CSE: OD, r = 0.96; OS, r = 0.97; nCSE: OD, r = 0.94; OS, r = 0.93 OS) and between eyes (CSE: examiner 1, r = 0.94; examiner 2, r = 0.95; nCSE: examiner 1, r = 0.95; examiner 2, r = 0.97). The correlation between CSE and nCSE was much lower (examiner 1: OD, r = 0.76; OS, r = 0.73; examiner 2: OD, r = 0.72; OS, r = 0.70). Prevalence of astigmatism was very low (1.6% ≥ 1.0 D). CONCLUSIONS The level of hyperopia was very high in these infants, and the offsetting tonic accommodation demonstrated by the difference between CSE and nCSE was much higher than in any previous report. Low amounts of infantile hyperopia and high astigmatism are associated with future myopia in the West. The Chinese neonates in this study had high amounts of hyperopia and little astigmatism, yet they are at high risk to become myopic.
منابع مشابه
The child self-refraction study results from urban Chinese children in Guangzhou.
OBJECTIVE To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. DESIGN Cross-sectional study. PARTICIPANTS Chinese school-children aged 12 to 17 years. METHODS Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm o...
متن کاملIdentification of infants with significant refractive error and strabismus in a population screening program using noncycloplegic videorefraction and orthoptic examination.
PURPOSE The second Cambridge Infant Vision Screening Program examined whether screening for accommodative errors by using videorefraction without cycloplegia could effectively serve as a first stage of screening for refractive errors, measured by standard cycloplegic retinoscopy. The screening also included an orthoptic examination for detection of strabismus. METHODS All infants born in the ...
متن کاملRetinoscopy in infants using a near noncycloplegic technique, cycloplegia with tropicamide 1%, and cycloplegia with cyclopentolate 1%.
PURPOSE This study compares retinoscopy in infants using a near noncycloplegic technique, cycloplegia with tropicamide 1%, and cycloplegia with cyclopentolate 1%. The study sample included 29 healthy, nonstrabismic infants 4 to 7 months of age (mean 5.71 months). METHODS Each study subject was examined at two separate visits an average of 2 weeks apart (mean [+/-SD] 14 +/- 9 days). The examin...
متن کاملAccuracy of noncycloplegic refraction in primary school children in southern Thailand.
OBJECTIVE To evaluate the accuracy of noncycloplegic refraction compared with cycloplegic refraction in diagnosing refractive error in primary school children in southern Thailand. MATERIAL AND METHOD This is a cross-sectional study. One hundred twenty children aged from 6-13 years who had visual acuity of 20/40 or worse in at least one eye were included. All the children underwent autorefrac...
متن کاملA comparison of manifest refractions, cycloplegic refractions and retinoscopy on the RMA-3000 autorefractometer in children aged 3 to 15 years
PURPOSE The study was conducted to compare the accuracy of readings of the RMA-3000 autorefractometer (Topcon, Tokyo, Japan) with traditional retinoscopy as a means of determining the approximate subjective refraction in children after cycloplegia. METHODS 142 children aged 3 to 15 years were included. All children had their refractive status measured with the RMA-3000 autorefractometer (nonc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 5 شماره
صفحات -
تاریخ انتشار 2011