Value and limitations of Doppler echocardiography in the quantification of stenotic mitral valve area: comparison of the pressure half-time and the continuity equation methods.
نویسندگان
چکیده
Two Doppler methods, the pressure half-time method proposed by Hatle and the method based on the equation of continuity, were used to estimate stenotic mitral valve area noninvasively, and the accuracy of these methods was examined in patients with and without associated aortic regurgitation. Mitral valve area determined at catheterization by the Gorlin formula was used as a standard of reference. The study population consisted of 41 patients with mitral stenosis, and 20 of the 41 patients had associated aortic regurgitation. According to the equation of continuity, mitral valve area was determined as a product of aortic or pulmonic annular cross-sectional area and the ratio of time velocity integral of aortic or pulmonic flow to that of the mitral stenotic jet. Mitral valve area was determined by the pressure half-time method as 220/pressure half-time, the time from the peak transmitral velocity to one-half the square root of the peak velocity on the continuous-wave Doppler-determined transmitral flow velocity pattern. The pressure half-time method tended to overestimate catheterization measurements, and the correlation coefficient for this relation was .69 (SEE = 0.44 cm2). The correlation coefficient improved to .90 when the patients with associated aortic regurgitation were excluded. Mitral valve areas determined by the continuity equation method correlated well with catheterization measurements at a correlation coefficient of .91 (SEE = 0.24 cm2), irrespective of the presence of aortic regurgitation. The ratio of the time-velocity integral or aortic or pulmonic flow to the time-velocity integral of mitral stenotic jet also correlated well with mitral valve area determined by catheterization at a correlation coefficient of .84 (SEE = 0.10).(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Impact of atrioventricular compliance on pulmonary artery pressure in mitral stenosis: an exercise echocardiographic study.
BACKGROUND The decay of the pressure gradient across a stenotic mitral valve is determined by the size of the orifice and net AV compliance (C(n)). We have observed a group of symptomatic patients, usually in sinus rhythm, characterized by pulmonary hypertension (particularly during exercise) despite a relatively large mitral valve area by pressure half-time. We speculated that this discrepancy...
متن کاملValidation of the proximal flow convergence method. Calculation of orifice area in patients with mitral stenosis.
BACKGROUND It has been proposed recently that measuring the flow convergence region proximal to an orifice by Doppler flow mapping can provide a means of calculating regurgitant flow rate. Although verified in experimental models, this approach is difficult to validate clinically because there is no ideal gold standard for regurgitant flows in patients. However, this method also can be used to ...
متن کاملDOPPLER ECHOCARDIOGRAPHY Calculation of aortic valve area by Doppler echocardiography : a direct application of the continuity equation
The continuity equation suggests that a ratio of velocities at two different cardiac valves is inversely proportional to the ratio of cross-sectional areas of the valves. To determine whether a ratio of mitral/aortic valve orifice velocities is useful in determining aortic valve area in patients with aortic stenosis, 10 control subjects and 22 patients with predominant aortic stenosis were exam...
متن کاملDoppler assessment of prosthetic valve orifice area. An in vitro study.
BACKGROUND Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. METHODS AND RESULTS Doppler-estimated valve areas were studied for their agreement with catheter-derived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-...
متن کاملCalculation of aortic valve area by Doppler echocardiography : a direct application of the continuity equation KENT
The continuity equation suggests that a ratio of velocities at two different cardiac valves is inversely proportional to the ratio of cross-sectional areas of the valves. To determine whether a ratio of mitral/aortic valve orifice velocities is useful in determining aortic valve area in patients with aortic stenosis, 10 control subjects and 22 patients with predominant aortic stenosis were exam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 77 1 شماره
صفحات -
تاریخ انتشار 1988