Experience with a Water-cooled X-ray Tube for Deep Therapy
نویسندگان
چکیده
Last year W. D. Coolidge and C. N. Moore described a watercooled high voltage X-ray tube which satisfactorily handles as much as 50 milliamperes at 250,000 volts (1). The best high voltage tube on the market before that time could not be used continuously with more than 8 M.A. at 200,000 volts. Thus an X-ray intensity could be obtained with the new tube many times as great as was possible before. Earlier experience in our Institute made us believe that increased in tensity was desirable. Dr. Gaylord, therefore, wished to have a water-cooled tube installed and Dr. Coolidge and the Victor Corporation agreed to furnish the Institute with one of the first tubes of t,his type, with advice as to where to order necessary equipment for the installation. Even with this information, it was rather difficult to arrive at an arrangement which was suitable for treatment.
منابع مشابه
Evaluation of a systemic change of Superficial X-ray tube characteristics
Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...
متن کاملPerformance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea
Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملNew x-ray tube performance in computed tomography by introducing the rotating envelope tube technology.
The future demands of computed tomography imaging regarding the x-ray source can be summarized with higher scan power, shorter rotation times, shorter cool down times and smaller focal spots. We report on a new tube technology satisfying all these demands by making use of a novel cooling principle on one hand and of a novel beam control system on the other hand. Nowadays tubes use a rotating an...
متن کاملQuality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran
Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...
متن کامل