Improving iterative 4D CBCT through the use of motion information

نویسندگان

  • Cyril Mory
  • Simon Rit
چکیده

In Image-Guided RadioTherapy (IGRT) of lung tumors, patients undergo a 4D CT, on the basis of which their treatment is planned. It is implicitely assumed that their breathing motion will not change much throughout the treatment, and remain close to what it was during the 4D CT acquisition. During the treatment, several cone beam CT acquisitions are performed, and used to re-position the patient. Obtaining a 4D reconstruction from this cone beam data would allow the therapists to check whether the breathing motion of the day still matches that of the planning CT, and if not, take appropriate corrective actions. Unfortunately, most tomography methods currently available are inadequate for such a task: static 3D reconstructions are pointless for motion assessment, respirationcorrelated reconstructions are affected by streak artifacts, and regularization techniques only bring limited improvement. Recently, regularized 4D methods have been proposed, in which the whole respiratory cycle is reconstructed at once. As these methods allow to explicitely enforce similarity between consecutive frames, they considerably improve image quality. In the case of IGRT, the motion information extracted from the 4D planning CT can be used to further improve the 4D reconstruction results. We describe a recent 4D reconstruction method (ROOSTER), propose its motion-compensated counterpart (MC-ROOSTER), and compare their results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Impact of scanning parameters and breathing patterns on image quality and accuracy of tumor motion reconstruction in 4D CBCT: a phantom study

Four-dimensional, cone-beam CT (4D CBCT) substantially reduces respiration-induced motion blurring artifacts in three-dimension (3D) CBCT. However, the image quality of 4D CBCT is significantly degraded which may affect its accuracy in localizing a mobile tumor for high-precision, image-guided radiation therapy (IGRT). The purpose of this study was to investigate the impact of scanning paramete...

متن کامل

Respiratory correlated cone beam CT.

A cone beam computed tomography (CBCT) scanner integrated with a linear accelerator is a powerful tool for image guided radiotherapy. Respiratory motion, however, induces artifacts in CBCT, while the respiratory correlated procedures, developed to reduce motion artifacts in axial and helical CT are not suitable for such CBCT scanners. We have developed an alternative respiratory correlated proc...

متن کامل

The 13th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine

Due to the limited number of projections at each phase, the image quality of a four-dimensional cone-beam CT (4D-CBCT) is often degraded, which decreases the accuracy of subsequent motion modeling. Various strategies have been proposed to enhance the image quality of 4D-CBCT. One of the promising methods is the simultaneous motion estimation and image reconstruction (SMEIR) approach. However, o...

متن کامل

Award Number : DAMD 17 - 03 - 1 - 0657 TITLE : Multiple Aperture Radiation Therapy ( MART ) for Breast Cancer

On-board imager (OBI) based cone-beam computed tomography (CBCT) has become available in radiotherapy clinics to accurately identify the target in the treatment position. However, due to the relatively slow gantry rotation (typically about 60 s for a full 360◦ scan) in acquiring the CBCT projection data, the patient’s respiratory motion causes serious problems such as blurring, doubling, streak...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015