The Leiden scavenging system: A simple and versatile apparatus to control air pollution in operating rooms.

نویسندگان

  • V Rejger
  • A G Burm
  • J Spierdijk
  • H Strokap
چکیده

A scavenging system which can be attached to a variety of anaesthetic machines and ventilators is described. Gas venting can occur via a central vacuum system, a suitable injector, fan or pump, through the exhaust duct of an air-conditioning system, or by a passive system. The resistance and back pressures applied to the anaesthetic apparatus are negligible. Leakage tests showed that the collected gases and vapours were substantially removed by the scavenging device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تراکم گاز بیهوشی نایتروس اکساید(O2N) در هوای اتاق‌های عمل جراحی و ریکاوری

Chronic exposure to N2O environmental pollution may influence the health of personnel working in operating and recovery rooms. Human studies have indicated that chronic exposure to N2O may decrease mental performance, audiovisual ability, and manual dexterity and may also cause adverse reproductive effects like reduced fertility, spontaneous abortion and neurological, renal, and liv...

متن کامل

Operating room air pollution: influence of anaesthetic circuit, vapour concentration, gas flow and ventilation.

Atmospheric halothane was sampled from three selected operating theatres and anaesthetic rooms during the middle of operating sessions. Two of the operating theatres studied were ventilated with total air exchange once every six minutes; the third operating theatre had no ventilation. End-tidal samples were obtained from anaesthetists. Halothane vapour concentrations were analysed by gas-liquid...

متن کامل

Nitrous oxide levels in operating room air with various gas flows.

Monitoring of nitrous oxide concentrations in operating rooms disclosed some leaks that had hitherto been unrecognized. Because nitrous oxide concentrations reported before 1967 had been obtained for the most part with high flows of the gas and without information concerning room air exchange, measurements were made of nitrous oxide levels during operations with an infra-red analyzer. after cor...

متن کامل

Compliance With Infection Control Guidelines in the Operating Rooms

Introduction: Compliance with the safety standards in the operating rooms, as one of the most complex work environments in the health care systems, is very important. One of the safety measures is the infection control standard.  Objective: This study aimed to investigate compliance with infection control standards in the operating rooms of teaching hospitals in Rasht City, Iran. Materials an...

متن کامل

تاثیر تهویه بر تراکم آلاینده‌های بیولوژیک هوا در یک اتاق بیمار مسلول

Background: Ventilation plays a crucial role in reducing the number of air transmitted pathogens in isolated rooms. Determination of the suitable type of ventilation system and the proper ventilating rate has always been a challenge. Patients’ bed arrangement and the location of the staff are also expected to influence the occupational exposure of the staffs’ to harmful airborne particles. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 53 12  شماره 

صفحات  -

تاریخ انتشار 1981