Lack of change in urate deposition by dual-energy computed tomography among clinically stable patients with long-standing tophaceous gout: a prospective longitudinal study

نویسندگان

  • Ashwin Rajan
  • Opetaia Aati
  • Ramanamma Kalluru
  • Gregory D Gamble
  • Anne Horne
  • Anthony J Doyle
  • Fiona M McQueen
  • Nicola Dalbeth
چکیده

INTRODUCTION Dual-energy computed tomography (DECT) has potential for monitoring urate deposition in patients with gout. The aim of this prospective longitudinal study was to analyse measurement error of DECT urate volume measurement in clinically stable patients with tophaceous gout. METHODS Seventy-three patients with tophaceous gout on stable therapy attended study visits at baseline and twelve months. All patients had a comprehensive clinical assessment including serum urate testing and DECT scanning of both feet. Two readers analysed the DECT scans for the total urate volume in both feet. Analysis included inter-reader intraclass correlation coefficients (ICCs) and limits of agreement, and calculation of the smallest detectable change. RESULTS Mean (standard deviation) serum urate concentration over the study period was 0.38 (0.09) mmol/L. Urate-lowering therapy was prescribed in 70 (96%) patients. The median (interquartile range) baseline DECT urate volume was 0.49 (0.16, 2.18) cm(3), and change in DECT urate volume was -0.01 (-0.40, 0.28) cm(3). Inter-reader ICCs were 1.00 for baseline DECT volumes and 0.93 for change values. Inter-reader bias (standard deviation) for baseline volumes was -0.18 (0.63) cm(3) and for change was -0.10 (0.93) cm(3). The smallest detectable change was 0.91 cm3. There were 47 (64%) patients with baseline DECT urate volumes <0.91 cm(3). Higher serum urate concentrations were observed in patients with increased DECT urate volumes above the smallest detectable change (P = 0.006). However, a relationship between changes in DECT urate volumes and serum urate concentrations was not observed in the entire group. CONCLUSIONS In patients with tophaceous gout on stable conventional urate-lowering therapy the measurement error for DECT urate volume assessment is substantially greater than the median baseline DECT volume. Analysis of patients commencing or intensifying urate-lowering therapy should clarify the optimal use of DECT as a potential outcome measure in studies of chronic gout.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Urate crystal deposition and bone erosion in gout: ‘inside-out’ or ‘outside-in’? A dual-energy computed tomography study

BACKGROUND It is currently unknown whether bone erosion in gout occurs through an 'inside-out' mechanism due to direct intra-osseous crystal deposition or through an 'outside-in' mechanism from the surface of bone. The aim of this study was to examine the mechanism ('outside-in' vs. 'inside-out') of monosodium urate (MSU) crystal deposition in bone erosion in gout. Specifically, we used three-d...

متن کامل

Tophaceous Gout in an Anorectic Patient Visualized by Dual Energy Computed Tomography (DECT)

BACKGROUND Gout is characterized by deposition of uric acid crystals (monosodium urate) in tissues and fluids. This can cause acute inflammatory arthritis. The 2015 ACR/EULAR criteria for the diagnosis of gout include dual energy computed tomography (DECT)-demonstrated monosodium urate crystals as a new criterion. DECT is a spectral decomposition that permits recognition of different types of t...

متن کامل

Imaging in gout - What can we learn from MRI, CT, DECT and US?

There are many exciting new applications for advanced imaging in gout. These modalities employ multiplanar imaging and allow computerized three-dimensional rendering of bone and joints (including tophi) and have the advantage of electronic data storage for later retrieval. High-resolution computed tomography has been particularly helpful in exploring the pathology of gout by investigating the r...

متن کامل

Dual-energy computed tomography has limited sensitivity for non-tophaceous gout: a comparison study with tophaceous gout

BACKGROUND Dual-energy computed tomography (DECT) is a new diagnostic tool for gout, but its sensitivity has not been established. Our goal was to assess the sensitivity of DECT for the detection of monosodium urate (MSU) deposits in non-tophaceous and tophaceous gout, both at the level of the patient and that of the individual joint or lesion. METHODS DECT was performed on 11 patients with c...

متن کامل

Presence of monosodium urate crystal deposition by dual-energy CT in patients with gout treated with allopurinol

OBJECTIVE Dual-energy CT (DECT) detects and quantifies monosodium urate (MSU) crystal deposition with high precision. This DECT study assessed crystal deposition in patients with gout treated with stable-dose allopurinol, and investigated potential clinical determinants for crystal deposition. METHODS Patients with gout treated with allopurinol ≥300 mg daily for at least 3 months were prospec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013