Small-animal single-photon emission computed tomographic imaging of the brain serotoninergic systems in wild-type and mdr1a knockout rats

نویسندگان

  • Noé Dumas
  • Marcelle Moulin-Sallanon
  • Nathalie Ginovart
  • Benjamin B. Tournier
  • Peggy Suzanne
  • Thomas Cailly
  • Frédéric Fabis
  • Sylvain Rault
  • Yves Charnay
  • Philippe Millet
چکیده

The pharmacokinetic properties of radiotracers are crucial for successful in vivo single-photon emission computed tomographic (SPECT) imaging. Our goal was to determine if MDR1A-deficient animals could allow better SPECT imaging outcomes than wild-type (WT) animals for a selection of serotoninergic radioligands. Thus, we compared the performances of 123I-p-MPPI, 123I-R91150, 123I-SB207710, and 123I-ADAM radioligands, for imaging of their respective targets (5-hydroxytryptamine [5-HT]1A, 5-HT2A, 5-HT4, and serotonin transporter [SERT]), in WT and Mdr1a knockout (KO) rats. With 123I-SB207710, virtually no SPECT signal was recorded in the brain of WT or KO animals. For 123I-p-MPPI, low nondisplaceable binding potentials (BPND, mean ± SD) were observed in WT (0.49 ± 0.25) and KO (0.89 ± 0.52) animals. For 123I-ADAM, modest imaging contrast was observed in WT (1.27 ± 0.02) and KO (1.31 ± 0.09) animals. For 123I-R91150, the BPND were significantly higher in Mdr1a KO (3.98 ± 0.65) animals compared to WT animals (1.22 ± 0.26). The pharmacokinetics of 123I-SB207710 and 123I-p-MPPI do not make them ideal tracers for [...] DUMAS, Noe, et al. Small-animal single-photon emission computed tomographic imaging of the brain serotoninergic systems in wild-type and mdr1a knockout rats. Molecular Imaging, 2014,

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small-Animal Single-Photon Emission Computed Tomographic Imaging of the Brain Serotoninergic Systems in Wild-Type and Mdrla Knockout Rats.

The pharmacokinetic properties of radiotracers are crucial for successful in vivo single-photon emission computed tomographic (SPECT) imaging. Our goal was to determine if MDR1A-deficient animals could allow better SPECT imaging outcomes than wild-type (WT) animals for a selection of serotoninergic radioligands. Thus, we compared the performances of 123I-p-MPPI, 123I-R91150, 123I-SB207710, and ...

متن کامل

Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review

Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...

متن کامل

In Vivo Quantification of 5-HT2A Brain Receptors in Mdr1a KO Rats with 123I-R91150 Single-Photon Emission Computed Tomography.

Our goal was to identify suitable image quantification methods to image 5-hydroxytryptamine2A (5-HT2A) receptors in vivo in Mdr1a knockout (KO) rats (i.e., P-glycoprotein KO) using 123I-R91150 single-photon emission computed tomography (SPECT). The 123I-R91150 binding parameters estimated with different reference tissue models (simplified reference tissue model [SRTM], Logan reference tissue mo...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Neural Imaging Using Single-Photon Avalanche Diodes

Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017