A comparison of tangent screen, goldmann, and humphrey perimetry in the detection and localization of occipital lesions.
نویسندگان
چکیده
OBJECTIVE To compare manual kinetic perimetry with tangent screen and Goldmann techniques and automated static perimetry with the Humphrey Field Analyzer in the detection and localization of occipital lobe lesions. DESIGN Prospective consecutive comparative case series. PARTICIPANTS Twelve patients with well-defined occipital lobe infarcts on magnetic resonance (MR) imaging were studied. MAIN OUTCOME MEASURES The patients were tested by tangent screen, Goldmann, and Humphrey perimetry (central 30-2 threshold program). The three visual fields were compared and correlated with MR images. RESULTS All three perimetric techniques detected the presence of postchiasmal lesions. However, localization of lesions differed with perimetric technique. Visual fields obtained from tangent screen and Goldmann perimetry were similar and corresponded well with the location of lesions on MR images in all 12 patients. Humphrey perimetry inaccurately localized the lesion to the proximal part of the postchiasmal pathway by revealing incongruous fields in two patients, failed to detect sparing of the posterior occipital cortex or occipital pole in four patients, and estimated a larger extent of damage in one patient when compared with MR images and manual perimetry. CONCLUSIONS All three perimetric techniques are satisfactory screening tests to detect occipital lesions. However, tangent screen and Goldmann perimetry provide information about the location and extent of lesions that is more consistent with prevailing knowledge of the effects of the lesion in the postgeniculate visual pathway.
منابع مشابه
A comparison of manual kinetic and automated static perimetry in obtaining ptosis fields.
OBJECTIVE To compare examination time and visual field loss for ptosis fields obtained with manual kinetic (Goldmann) perimetry and automated static (Humphrey) perimetry. METHODS Both eyes of 12 patients with bilateral aponeurogenic ptosis were prospectively examined using Goldmann and Humphrey (ptosis protocol) perimetry with the eyelids ptotic and taped into a normal position. RESULTS Bil...
متن کاملA comparison of Goldmann and Humphrey automated perimetry in patients with glaucoma.
Humphrey automated threshold perimetry (Program 30-2) was performed on 42 eyes of 25 patients with glaucoma to determine both the sensitivity and specificity of automated perimetry in detecting glaucomatous visual field defects. Automated perimetry sensitivity was 90.38%, while automated perimetry specificity was 91%. Fifty-two patients and a technician took part in a survey to determine their ...
متن کاملMechanisms mediating visual detection in static perimetry.
PURPOSE The usual stimuli in static perimetry are white-light luminance increments. However, the specific visual detection mechanisms involved in perimetry are unknown because all classes of neural mechanisms are sensitive to spectrally broadband stimuli. The objective of this study was to determine the relative sensitivities of nonopponent and opponent detecting mechanisms under standard perim...
متن کاملStudy of Optimal Perimetric Testing in Children (OPTIC): Feasibility, Reliability and Repeatability of Perimetry in Children
PURPOSE To investigate feasibility, reliability and repeatability of perimetry in children. METHODS A prospective, observational study recruiting 154 children aged 5-15 years, without an ophthalmic condition that affects the visual field (controls), identified consecutively between May 2012 and November 2013 from hospital eye clinics. Perimetry was undertaken in a single sitting, with standar...
متن کاملRepresentation of the visual field in the human occipital cortex: a magnetic resonance imaging and perimetric correlation.
OBJECTIVES To evaluate the retinotopic map of the human occipital cortex by correlating magnetic resonance imaging (MRI) findings with visual field defects in patients with occipital lobe infarcts and to assess the compatibility between our cliniconeuroimaging findings and the location of lesions predicted by the classic Holmes map and a revised map. METHODS Magnetic resonance images were obt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 107 3 شماره
صفحات -
تاریخ انتشار 2000