A Novel Method of Multi-Information Acquisition for Electromagnetic Flow Meters
نویسندگان
چکیده
In this paper, a novel method is proposed for multi-information acquisition from the electromagnetic flow meter, using magnetic excitation to measure the fluid velocity and electrochemistry impedance spectroscopy (EIS) for both the fluid quality and the contamination level of the transducer. The impedance spectra of the transducer are measured with an additional electrical stimulus in series with the electrode measurement loop. The series connection mode instead of the parallel one improves the signal-to-noise ratio (SNR) of the fluid velocity measurement and offers a wide range of impedance measurements by using a sample capacitance. In addition, a multi-frequency synchronous excitation source is synthesized based on the method of dual-base power sequences for fast EIS measurement. The conductivity measurements in the range of 1.7 μS/cm-2 mS/cm showed a relatively high accuracy with a measurement error of 5%, and the electrode adhesion detection on both with coating and no coating showed the ability of the qualitative determination of the electrode adhesion, which validated the feasibility of the multi-information acquisition method for the electromagnetic flow meter (EMFM).
منابع مشابه
Numerical Simulation and Verification of Weight Function of Electromagnetic Flow Meter with Non-insulation Pipe Wall
Weight function distributions for an electromagnetic flow meter with a non-insulating pipe are numerically simulated and verified. The weight function distribution is very important for solution of flow velocity of distribution. In this paper, a finite element method (FEM) is used for solving the weight function distribution for this novel electromagnetic flow meter. First of all, a numerical s...
متن کاملDoes whole body exposure to GSM-950 MHz electromagnetic fields affect acquisition and consolidation of spatial information in rats?
Background: This study was planned to examine the effects of whole-body exposure to GSM-950 MHz electromagnetic fields (EMFs) on acquisition and consolidation of spatial memory in rats using a water maze task. Materials and Methods: In experiment 1, the animals were given two blocks of five trials per day for three consecutive days in a water maze task. The interval between blocks was 4h...
متن کاملA Novel Adapted Multi-objective Meta-heuristic Algorithm for a Flexible Bi-objective Scheduling Problem Based on Physics Theory
We relax some assumptions of the traditional scheduling problem and suggest an adapted meta-heuristic algorithm to optimize efficient utilization of resources and quick response to demands simultaneously. We intend to bridge the existing gap between theory and real industrial scheduling assumptions (e.g., hot metal rolling industry, chemical and pharmaceutical industries). We adapt and evalua...
متن کاملA Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information
Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...
متن کاملA novel ranking method for intuitionistic fuzzy set based on information fusion and application to threat assessment
A novel ranking method based on multi-time information fusion is proposed for intuitionistic fuzzy sets (IFSs) and applied to the threat assessment problem, a multi-attribute decision making (MADM) one. This method integrates a designed intuitionistic fuzzy entropy (IFE), the closeness degree of technique for order preference by similarity to ideal solution (TOPSIS), the decision maker¡¯s (DM¡¯...
متن کامل