Comparison of non-invasive and implanted telemetric measurement of blood pressure and electrocardiogram in conscious beagle dogs.
نویسندگان
چکیده
INTRODUCTION The objective of this study was to evaluate the ability of a non-invasive telemetry monitoring system to detect and quantify changes in blood pressure and electrocardiogram (ECG) parameters in response to vehicle, L-NAME or minoxidil administration to freely moving beagle dogs. Data from a non-invasive telemetry monitoring system were compared to data captured from an invasive telemetry implant in the same animals. METHODS Blood pressure and ECG data were simultaneously acquired from male dogs using a non-invasive and an invasive implanted telemetry system for 2 hours predose and 24 hours post dosing with vehicle (n=5), minoxidil at 1 mg/kg (n=4) and L-NAME at 10 mg/kg (n=5) on separate test days. Values for mean blood pressure, systolic blood pressure, diastolic blood pressure, pulse pressure, heart rate, RR, PR, QRS, QT and QTcL (heart rate corrected QT interval) interval were reported for both methods. RESULTS Statistically significant reductions in blood pressure and pulse pressure and increases in heart rate, with associated ECG interval changes were apparent following dosing with minoxidil using both methods. Statistically significant increases in blood pressure and pulse pressure were apparent following dosing with L-NAME when using the invasive telemetry system, changes were apparent when using the non-invasive telemetry system, however, no change was apparent for pulse pressure, they were of shorter duration and not statistically significant. Statistically significant decreases in heart rate, with associated changes in ECG intervals, were apparent following treatment with L-NAME for both invasive and non-invasive methods. DISCUSSION This study shows that the non-invasive system can be successfully used to acquire both ECG and blood pressure data in freely moving jacketed dogs for at least 26 hours, yet requires further technique refinement to improve system sensitivity to detect smaller changes in blood pressure.
منابع مشابه
Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملShort-term effects of oral dronedarone administration on cardiac function, blood pressure and electrocardiogram in conscious telemetry dogs
Dronedarone is a multichannel blocking antiarrhythmic drug that has been used for management of atrial fibrillation in humans, but the data in veterinary medicine are inadequate. The objective of this study was to determine the short-term effects of oral dronedarone on cardiac inotropy and lusitropy, blood pressure and electrocardiogram (ECG) in healthy dogs. A total of 6 beagle dogs were instr...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملCircadian changes in the QT variability index in the beagle dog.
1. QT variability is a non-invasive marker of cardiac repolarization lability and a higher QT variability is associated with sudden death. No data exist as to the circadian fluctuations in QT variability and the QT variability index (QTvi) in the canine. The purpose of the present investigation was to explore QT interval variability over 24 h in the healthy dog. 2. Continuous lead II electrocar...
متن کاملتخمین بدون کاف فشارخون مبتنی بر ویژگیهای زمانی سیگنال نبض
Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of pharmacological and toxicological methods
دوره 66 2 شماره
صفحات -
تاریخ انتشار 2012