Contrast echocardiography for myocardial perfusion imaging using intravenous agents: progress and promises.

نویسندگان

  • R Amyot
  • M A Morales
  • D Rovai
چکیده

AIMS This article is a convenient overview to assist the interested echocardiographist towards acquiring his own experience in the field of myocardial perfusion imaging using intravenous contrast agents. This goal is now pursued in many centres, since contrast echo holds the advantages of cardiac ultrasound (non-invasiveness, high spatial and temporal resolution, wide availability, use of non-ionizing radiation), and because a variety of transpulmonary agents-together with a spectrum of imaging modalities-are becoming available. METHODS AND RESULTS Many technical considerations need to be addressed for optimal myocardial perfusion imaging: characteristics of the contrast medium (air-filled or perfluorocarbon filled and/or encapsulated agents), modality of administration (bolus injection or continuous infusion) and interaction between microbubbles and ultrasound (dependency on power output). Moreover, intermittent harmonic imaging, intermittent harmonic power Doppler, pulse inversion and amplitude modulation imaging have all been developed to enhance microbubble detection over myocardial tissue. These new acquisition modalities also yield specific artifacts impacting on myocardial perfusion assessment. Finally, acute myocardial infarction and chronic ischaemic heart disease (at baseline and during stress) are the most studied clinical models for perfusion imaging with contrast echo, and are reviewed in this article. CONCLUSION Perfusion imaging with intravenous contrast agents has never been as close to widespread clinical use as it is today, but many methodological issues remain unsettled before the wish of the contrast echocardiographist comes true: that is, a cheap, user-friendly and widely available technology that would disclose new information in echocardiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The first performance of myocardial perfusion scintigraphy, post intravenous Dipyridamole injection

SUMMARY Dipyridamolc-Thallium imaging is a relatively safe and accurate method to evaluate myocardial perfusion in patients who arc unable to exercise to a maximal exertion (5,6,8,9). A 51year-old woman was admitted to Taleghani hospital with clinical symptoms and signs of coronary artery disease. Intravenous dipyridamote-Thallium scan was performed in this case. In multiple views obtained f...

متن کامل

Contrast echocardiography: from left ventricular opacification to myocardial perfusion. Are the promises to be realised?

V irtually every cardiac imaging technique utilises contrast agents, yet the adoption of ultrasound contrast agents into the routine practice of echocardiography has been slow. The commercial and clinical promise of contrast echo has not yet been fulfilled and we are truly standing at the crossroad between success and failure of the technique. In this introductory article to the mini-symposium ...

متن کامل

Safety of dobutamine stress real-time myocardial contrast echocardiography.

OBJECTIVES The aim of this study was to determine the safety of dobutamine stress myocardial perfusion imaging (MPI) obtained by real-time contrast echocardiography (RTCE) and intravenous ultrasound contrast in a large cohort of patients with suspected coronary artery disease (CAD). BACKGROUND Despite the increasing number of studies showing the potential clinical utility of myocardial contra...

متن کامل

Dobutamine stress MRI for the assessment of coronary artery disease: expanding our field of view.

tolic function will improve after coronary revascularization (viability testing) [3]. In general, stress CMR is frequently performed with one of two protocols. The more commonly used protocol is myocardial perfusion imaging, which involves intravenous administration of a vasodilator (i.e., adenosine). Stress perfusion CMR allows the evaluation of resting LV contraction as well as detection of m...

متن کامل

Simulation and patient studies of scatter correction in cardiac SPECT imaging

Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 1 4  شماره 

صفحات  -

تاریخ انتشار 2000