Isotope cluster detection and validation
نویسنده
چکیده
In [1] we propose an approach for the exhaustive detection and mass-specific validation of isotope clusters. In this approach we perform an targeted peak picking for the detection of isotopoloue features and we perform a massspecific validation of putative isotope clusters. The approach is implemented in the following workflow using functions from xcms [2] and CAMERA [3]. First, we perform peak picking without any prior knowledge which we denote as traditional peak picking. Here, we use the centWave algorithm [4] which applies a heuristic for the detection of ROIs (ROI identification step). Given the set of detected ROIs, chromatographic peaks are extracted using continuous wavelet transformation (ROI examination step). This step results in a peak table with one row for each detected feature and one column for each feature property such as m/z, retention time, integrated peak area, and signal-to-noise ratio. Second, we perform the proposed targeted peak picking as described in [1]. Here, a set of isotope ROIs is predicted on basis of the previously extracted peak table. Given the set of predicted isotope ROIs, chromatographic peaks are extracted using continuous wavelet transformation (ROI examination step). Notably, this ROI examination step is identical to the ROI examination step in the traditional peak picking step with the exception that we use relaxed peak picking parameters this time. This step results in an extended peak table which is enriched with features corresponding to isotope peaks. Third, we extract pseudospectra from the extended peak table [3]. This step aims at the extraction of compound spectra on basis of the retention times, but multiple coeluting compounds are potentially assigned to the same spectrum which is the reason for the usage of the term pseudospectrum. In case of multiple raw data files a retention time correction (xmcs function retcor) can be advisable prior to the extraction of pseudospectra. This step results
منابع مشابه
Prediction, Detection, and Validation of Isotope Clusters in Mass Spectrometry Data
Mass spectrometry is a key analytical platform for metabolomics. The precise quantification and identification of small molecules is a prerequisite for elucidating the metabolism and the detection, validation, and evaluation of isotope clusters in LC-MS data is important for this task. Here, we present an approach for the improved detection of isotope clusters using chemical prior knowledge and...
متن کاملCalculation of the rotational bands for the 20Ne isotope
The phenomenon of clustering in light nuclei is one of the interesting topics while its study is difficult. In this article, a simple model (the two-particle model which includes a core and a cluster) is presented for the investigation of the positive and the negative parity of rotational bands of 20Ne isotope. The Deng-Fan and the Hellman potentials are considered as the core and the cluster p...
متن کاملAnalysis of N-nitrosamines in water by isotope dilution gas chromatography-electron ionisation tandem mass spectrometry.
A method has been developed for the determination of eight N-nitrosamines in drinking water and treated municipal effluent. The method uses solid phase extraction (SPE), gas chromatography (GC) and analysis by tandem mass spectrometry (MS-MS) with electron ionization (EI). The target compounds are N-nitrosodimethylamine (NDMA), N-nitrosomethyethylamine (NMEA), N-nitrosodiethylamine NDEA), N-nit...
متن کاملCluster Validity Measures Dynamic Clustering Algorithms
Cluster analysis finds its place in many applications especially in data analysis, image processing, pattern recognition, market research by grouping customers based on purchasing pattern, classifying documents on web for information discovery, outlier detection applications and act as a tool to gain insight into the distribution of data to observe characteristics of each cluster. This ensures ...
متن کاملMethod for Validation of Antenna Calibration Measurements
Antenna calibration measurement is a specific type of multidimensional measurement with a plenty of influencing factors. In order to validate these measurements, the specialized methodology with a goal of improving the calibration procedures has been developed. The method is based on cluster analysis of existing antenna calibration measurements in a combination with tailored outlier detection m...
متن کامل