Rapid maxillary expansion screws on the test bench--a pilot study.

نویسندگان

  • Alfred Peter Muchitsch
  • B Wendl
  • H Winsauer
  • M Pichelmayer
  • M Payer
چکیده

In order to apply high, short-term forces during rapid maxillary expansion (RME) to the sutures of the maxilla with minimum loss of force and without causing unwanted side-effects (dentoalveolar tipping, etc.), the appliance should be as rigid as possible. The retention arms of the RME screws, representing a particularly vulnerable and stressed weak point of RME appliances, were the focus of this laboratory technical study. Retention arms of 16 types of RME screws comprising four arms and one with eight arms were examined using a three-point bending test. According to their ability to absorb the applied bending loads, the screws were classified in product groups from 1 (highest) to 6 (lowest). Fifteen of the tested retention arms (stainless steel), despite having the same diameter (1.48-1.49 mm), differed up to 69.81 per cent between the highest (288.0 N) and lowest (169.6 N) maximum force parameters and up to 66.40 per cent between the highest (3325.9 N/mm(2)) and lowest (1998.7 N/mm(2)) maximum bending stress parameters. Due to optimum formability, though reduced rigidity, a titanium screw for nickel-sensitive patients (group 6) displayed the lowest force and bending tension values. The stainless steel double arms of the eight-arm screw device welded on both ends displayed the highest force data. The mean ductilities of the groups with the most and least rigid single steel arms differed by 22.77 per cent. Statistical analysis using the Pearson correlation coefficient revealed a significant indirect correlation between ductility and both maximum force (r = -0.780, P < 0.001) and maximum bending stress (r = -0.778, P < 0.001). The SUPERscrews, the Tiger Dental four-arm screw (group 1), and the eight-arm screw displayed the highest capacity to absorb an applied bending load. The screws in groups 3-6 appear acceptable for RME during the pre-pubertal period, whereas in the pubertal and post-pubertal period, groups 1 and 2 are sufficient. In early adulthood only the screws in group 1 and especially the eight-arm screw seem advisable, as mechanical demands increase with age.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of mechanical properties of three different screws for rapid maxillary expansion

BACKGROUND The aim of this in vitro study was the evaluation of the mechanical properties the screws for rapid maxillary expansion (RME). METHODS Three commercially available screws for RME were tested: Leone A2620; Dentaurum Hyrax; Forestadent Palatal Split Screw. All expansion screws were 10 mm in size. For the evaluation of mechanical properties, the screws for RME were adjusted using the ...

متن کامل

Bone-Borne Maxillary Expansion and Traditional Rapid Maxillary Expansion: A Systematic Review and Meta-Analysis

Introduction: The aim of this study was to perform a systematic review and meta-analysis to compare the effect of bone-borne expansion (BBE) and tooth-borne expansion (TBE) in patients with maxillary constriction. Methods: Electronic databases, including MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials, were searched up to February 2019. Elig...

متن کامل

Surgically assisted rapid palatal expansion with tent screws and a custom-made palatal expander: a case report

Rapid palatal expansion(RPE) with the tooth-born appliance is not sufficient to apply to the patients with periodontal problem or insufficient tooth anchorage, and it leads to tipping of the anchorage teeth and increasing teeth mobility and root resorption. To avoid these disadvantages, we present the case using palatal screws and custommade palatal expander. A 23-year-old patient underwent sur...

متن کامل

Effects of palate depth, modified arm shape, and anchor screw on rapid maxillary expansion: a finite element analysis.

OBJECTIVES This study examined the effects of palate depth, modifications of the arm shape, and anchor screw placement in the mid-palatal area on rapid maxillary expansion (RME) using finite element (FE) analysis. MATERIALS AND METHODS Three-dimensional FE models were constructed that included the maxilla (cortical and cancellous bone), maxillary sinus, maxillary first molar and first premola...

متن کامل

Hybrid Rapid Palatal Expansion With 2 Mini- Screws: A Case Report

A hybrid expander is a newly designed bone-anchored expander consisting of 2 mini-screws and palatal acrylic; it does not cover any teeth. The aim of this case report is to present the treatment of a patient with transversal maxillary deficiency by hybrid expander. An 11.4-year-old female patient came to our clinic complaining about the appearance of her teeth. She had a narrow maxillary arch, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 33 3  شماره 

صفحات  -

تاریخ انتشار 2011