Accuracy and precision of desktop spirometers in general practices.

نویسندگان

  • Tjard R J Schermer
  • Eddy H A Verweij
  • Riet Cretier
  • Annelies Pellegrino
  • Alan J Crockett
  • Patrick J P Poels
چکیده

BACKGROUND Spirometry has become an essential tool for general practices to diagnose and monitor chronic airways diseases, but very little is known about the performance of the spirometry equipment that is being used in general practice settings. The use of invalid spirometry equipment may have consequences on disease diagnosis and management of patients. OBJECTIVES To establish the accuracy and precision of desktop spirometers that are routinely used in general practices. METHODS We evaluated a random sample of 50 spirometers from Dutch general practices by testing them on a certified waveform generator using 8 standard American Thoracic Society waveforms to determine accuracy and precision. Details about the brand and type of spirometers, year of purchase, frequency of use, cleaning and calibration were inquired with a study-specific questionnaire. RESULTS 39 devices (80%) were turbine spirometers, 8 (16%) were pneumotachographs, and 1 (2%) was a volume displacement spirometer. Mean age of the spirometers was 4.3 (SD 3.7) years. Average deviation from the waveform generator reference values (accuracy) was 25 ml (95% confidence interval 12-39 ml) for FEV(1) and 27 ml (10-45 ml) for FVC, but some devices showed substantial deviations. FEV(1) deviations were larger for pneumotachographs than for turbine spirometers (p < 0.0031), but FVC deviations did not differ between the two types of spirometers. In the subset of turbine spirometers, no association between age and device performance was observed. CONCLUSIONS On average, desktop spirometers in general practices slightly overestimated FEV(1) and FVC values, but some devices showed substantial deviations. General practices should pay more attention to the calibration of their spirometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Testing spirometers: are the standard curves of the american thoracic society sufficient?

BACKGROUND The performance of spirometers is often measured only under ideal conditions, with a mechanical simulator reproducing the expiratory standard American Thoracic Society (ATS) curves generated by a computer. Studies have questioned the value of these results in real-life conditions. The aim of this study was to evaluate the accuracy and precision of 5 office spirometers with a flow-vol...

متن کامل

کاربرد سنجش از دور چند زمانی در تعیین سطح زیرکشت

Precision farming aims to optimize field-level management by providing information on production rate, crop needs, nutrients, pest/disease control, environmental contamination, timing of field practices, soil organic matter and irrigation. Remote sensing and GIS have made huge impacts on agricultural industry by monitoring and managing agricultural lands. Using vegetation indices have been wide...

متن کامل

Developing a Method for Increasing Accuracy and Precision in Measurement System Analysis: A Fuzzy Approach

Measurement systems analysis (MSA) has been applied in different aspect of industrial assessments to evaluate various types of quantitative and qualitative measures. Qualification of a measurement system depends on two important features: accuracy and precision. Since the capability of each quality system is severely related to the capability of its measurement system, the weakness of the two...

متن کامل

بررسی دیدگاه پرستاران در مورد تاثیر نظام اطلاعات بیمارستان بر روی فرآیندهای پرستاری در بیمارستان فارابی

Background and Aim: Nurses are major end-users of hospital information systems (HIS). Therefore their views about strengths and weaknesses of the system are important, and, if addressed, could improve the software system and, in turn, the hospital performance. The purpose of this study was to assess the nurses' perspective about the impact of HIS in Farabi Hospital on nursing process in terms o...

متن کامل

Stability of the EasyOne ultrasonic spirometer for use in general practice.

OBJECTIVE AND BACKGROUND Spirometry is recommended for the diagnosis and management of chronic respiratory diseases in the community. Spirometer accuracy is critical, but few general practitioners meet the American Thoracic Society and European Respiratory Society (ATS/ERS) recommendation for daily calibration. The aim of this study was to assess the accuracy and stability of a portable ultraso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiration; international review of thoracic diseases

دوره 83 4  شماره 

صفحات  -

تاریخ انتشار 2012