A three alternative tracking paradigm to measure vernier acuity of older infants.

نویسندگان

  • R E Manny
  • S A Klein
چکیده

Vernier acuity was measured in infants 1 to 14 months of age using a dynamic three alternative tracking paradigm. The location of the vernier offset would move randomly to one of three screen locations. An observer, unaware of the stimulus location, viewed the infant from behind a screen and guessed the position of the vernier offset. The magnitude of the vernier offset was controlled by a staircase and the results were analyzed using a broken line psychometric function. These thresholds were compared to thresholds obtained from the same infants during the same session with a two alternative forced choice preferential looking paradigm. Differences in the results of these two procedures and those reported previously in the literature are discussed in terms of the differences in the nature of the visual stimuli, one containing motion and one without motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of vernier acuity development using the “Equivalent Intrinsic Blur” paradigm

Vernier acuity in human infants is more than two orders of magnitude poorer than in adults and does not appear to reach adult levels until well beyond the first postnatal year. One source of these developmental differences in vernier acuity may be the presence of levels of intrinsic blur that are higher in infants than in adults. We investigated this hypothesis by measuring vernier acuity in 3-...

متن کامل

Measurement of position acuity in strabismus and amblyopia: specificity of the vernier VEP paradigm.

PURPOSE An objective measure of positional acuity is desirable in the nonverbal clinical population. This study was conducted to investigate the specificity of the vernier VEP as a measure of positional acuity, evaluating the potential confound of asymmetric motion responses that may be present in some groups of patients. These motion responses could masquerade as position-specific responses, s...

متن کامل

Adult vernier thresholds do not increase with age; vernier bias does.

Vernier acuity and vernier bias were examined in persons aged 20 to 79 years using a method of adjustments. Vernier bias (mean error) showed a sharp increase between 35 and 45. Vernier acuity (standard deviation or precision of alignment) did not vary significantly with age. These different results indicate the importance of separate evaluation of acuity and bias. Vernier acuity is little affec...

متن کامل

Neural fine tuning during Vernier acuity training?

A superposition masking and summation to threshold paradigm was employed before and after unmasked Vernier acuity training to measure sensory changes of offset analysing mechanisms. Masking functions show a uniform downward translation after training and detection data reveal higher sensitivities to compound Gabor gratings in the post-test. These findings confirm the existence of learning relat...

متن کامل

Spatial scale of visual analysis for vernier acuity does not vary over time

The visual system filters spatial pattern through a range of narrowly tuned spatial mechanisms, but the rules by which the outputs of these mechanisms are combined across time to extract precise geometrical information are not yet clear. One hypothesis is that spatial analysis shifts over time from coarse to finer spatial scales, in order to extract fine spatial information. An alternative hypo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision research

دوره 25 9  شماره 

صفحات  -

تاریخ انتشار 1985