Embedded nanomicro syringe on chip for molecular therapy

نویسندگان

  • Muhammad Arif Jalil
  • Nathaporn Suwanpayak
  • Kathawut Kulsirirat
  • Saisudawan Suttirak
  • Jalil Ali
  • Preecha P Yupapin
چکیده

BACKGROUND A novel nanomicro syringe system was proposed for drug storage and delivery using a PANDA ring resonator and atomic buffer. A PANDA ring is a modified optical add/drop filter, named after the well known Chinese bear. In principle, the molecule/drug is trapped by the force generated by different combinations of gradient fields and scattering photons within the PANDA ring. A nanomicro needle system can be formed by optical vortices in the liquid core waveguide which can be embedded on a chip, and can be used for long-term treatment. By using intense optical vortices, the required genes/molecules can be trapped and transported dynamically to the intended destinations via the nanomicro syringe, which is available for drug delivery to target tissues, in particular tumors. The advantage of the proposed system is that by confining the treatment area, the effect can be decreased. The use of different optical vortices for therapeutic efficiency is also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Embedded Memory Test Strategies and Repair

The demand of self-testing proportionally increases with memory size in System on Chip (SoC). SoC architecture normally occupies the majority of its area by memories. Due to increase in density of embedded memories, there is a need of self-testing mechanism in SoC design. Therefore, this research study focuses on this problem and introduces a smooth solution for self-testing.  In the proposed m...

متن کامل

Lab-in-a-syringe using gold nanoparticles for rapid immunosensing of protein biomarkers.

We have developed a paper and gold nanoparticle (AuNP)-based lab-in-a-syringe (LIS) for immunosensing of biomarkers. This simple diagnostic device features simultaneous sampling and vertical-flow operation, which means that unlike typical immunosensors, it does not suffer from any delay between sampling and detection. It can handle large-volume, low-concentration samples for analysis in diverse...

متن کامل

Self-powered switch-controlled nucleic acid extraction system.

Over the past few decades, lab-on-a-chip (LOC) technologies have played a great role in revolutionizing the way in vitro medical diagnostics are conducted and transforming bulky and expensive laboratory instruments and labour-intensive tests into easy to use, cost-effective miniaturized systems with faster analysis time, which can be used for near-patient or point-of-care (POC) tests. Fluidic p...

متن کامل

Hand-held syringe as a portable plastic pump for on-chip continuous-flow PCR: miniaturization of sample injection device.

On-chip continuous-flow polymerase chain reactions (PCRs) generally require peripheral apparatus such as a pump for injecting a sample liquid into the fluidic channel. This makes the overall instrumentation bulky, limiting integration. In this study, we propose a new scheme for injecting a sample employing a hand-held syringe as a portable plastic pump, and apply it to an on-chip continuous-flo...

متن کامل

Syringe-pump-induced fluctuation in all-aqueous microfluidic system implications for flow rate accuracy.

We report a new method to display the minute fluctuations induced by syringe pumps on microfluidic flows by using a liquid-liquid system with an ultralow interfacial tension. We demonstrate that the stepper motor inside the pump is a source of fluctuations in microfluidic flows by comparing the frequencies of the ripples observed at the interface to that of the pulsation of the stepper motor. W...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011