Biodegradation of 4-chlorophenol in an airlift inner loop bioreactor with mixed consortium: effect of HRT, loading rate and biogenic substrate
نویسندگان
چکیده
In the present work, removal of 4-chlorophenol (4-CP) by the mixed microbial consortium was evaluated in an airlift inner loop bioreactor. During the study, the effect of various reactor parameters such as hydraulic retention time (HRT), biogenetic substrate concentration, loading rate, and initial substrate concentration on the removal efficiency of 4-CP was investigated. Bioreactor showed a maximum removal rate of 16.59 mg/L/h at the optimum conditions of 24 h HRT, 400 mg/L initial 4-CP, and 0.2 g/L peptone. The optimum HRT found was 24 h after that the washout occured, and the degradation efficiency almost dropped to 50 % at 18 h HRT. Effect of peptone showed that lower concentration of peptone improves 4-CP removal efficiency of the bioreactor. Also, the mixed consortium had utilized 4-CP as a carbon source, as evidenced by the increasing biomass concentration with 4-CP at constant peptone concentration. The presence of 5-chloro 2-hydroxymuconic semialdehyde in the reactor infers that the mixed consortium has followed the meta-cleavage pathway for 4-CP degradation.
منابع مشابه
Biodegradation of 2,4-dichlorophenol and phenol in an airlift inner-loop bioreactor immobilized with Achromobacter sp
An airlift inner-loop bioreactor packed with honeycomb-like ceramic as the carrier was developed and its capacity to immobilize microorganism was studied through adding bacteria, Achromobacter sp., capable of degrading 2,4-dichlorophenol (2,4-DCP), directly to the reactor under continuous operation. Effects of phenol in the feed with 2,4-DCP on 2,4-DCP removal were investigated under fed-batch ...
متن کاملPhenol Biodegradation Kinetics in the Presence of Supplimentary Substrate
Biodegradation of phenol in the presence of glucose as a supplementary substrate was investigated with mixed microbial consortium isolated from waste effluent of coke-steel factory. Batch experiments were carried out at room temperature and pH value of 7. Initial phenol and glucose concentrations were in the range of 25-1000 mg/l and 500-3000 mg/l, respectively. In a dual substrates system the ...
متن کاملHydrocarbon contaminated water remediation using a locally constructed multi-stage bioreactor incorporated with media filtration
The present study investigated the coupling effect of biodegradation and media filtration in treating hydrocarbon contaminated water. The study recorded reductions in total petroleum hydrocarbon, total dissolved solids, turbidity and microbial load. The study was essentially a simulated pump and treat process that involved the pumping of hydrocarbon contaminated water for treatment in a locally...
متن کاملComparison of Different Loop Bioreactors Based on Hydrodynamic Characteristics, Mass Transfer, Energy Consumption and Biomass Production from Natural Gas
The performance of a forced-liquid Vertical Tubular Loop Bioreactor (VTLB), a forced-liquid Horizontal Tubular Loop Bioreactor (HTLB) and a gas-induced External Airlift Loop Bioreactor (EALB) were compared for production of biomass from natural gas. Hydrodynamic characteristics and mass transfer coefficients were determined as functions of design parameters, physical properties of gases as ...
متن کاملHydrodynamic Behaviour in a New Gas-liquid-solid Inverse Fluidization Airlift Bioreactor
A gas-liquid-solid inverse uidization airlift bioreactor was proposed by combining advantages of external-loop airlift reactors and inverse uidized beds. This airlift bioreactor comprises a gas-liquid riser, a gas separator, a liquid-solid inverse uidized downcomer and a bottom connector. The effects of the gas velocity and the particle loading on the gas holdup in the riser and the liqui...
متن کامل