An improved vaseline gap voltage clamp for skeletal muscle fibers

نویسندگان

  • B Hille
  • D T Campbell
چکیده

A Vaseline gap potentiometric recording and voltage clamp method is developed for frog skeletal muscle fibers. The method is based on the Frankenhaeuser-Dodge voltage clamp for myelinated nerve with modifications to improve the frequency response, to compensate for external series resistance, and to compensate for the complex impedance of the current-passing pathway. Fragments of single muscle fibers are plucked from the semitendinosus muscle and mounted while depolarized by a solution like CsF. After Vaseline seals are formed between fluid pools, the fiber ends are cut once again, the central region is rinsed with Ringer solution, and the feedback amplifiers are turned on. Errors in the potential and current records are assessed by direct measurements with microelectrodes. The passive properties of the preparation are simulated by the "disk" equivalent circuit for the transverse tubular system and the derived parameters are similar to previous measurements with microelectrodes. Action potentials at 5 degrees C are long because of the absence of delayed rectification. Their shape is approximately simulated by solving the disk model with sodium permeability in the surface and tubular membranes. Voltage clamp currents consist primarily of capacity currents and sodium currents. The peak inward sodium current density at 5 degrees C is 3.7 mA/cm2. At 5 degrees C the sodium currents are smoothly graded with increasing depolarization and free of notches suggesting good control of the surface membrane. At higher temperatures a small, late extra inward current appears for small depolarizations that has the properties expected for excitation in the transverse tubular system. Comparison of recorded currents with simulations shows that while the transverse tubular system has regenerative sodium currents, they are too small to make important errors in the total current recorded at the surface under voltage clamp at low temperature. The tubules are definitely not under voltage clamp control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical Signals from Surface and T System Membranes in Skeletal Muscle Fibers Experiments with the Potentiometric Dye NK 2367 JUDITH

Absorbance signals were recorded from cut single skeletal muscle fibers stained with the nonpenetrating potentiometric dye NK2367 and mounted in a three-vaseline-gap voltage clamp . The characteristics of the optical signals recorded under current and voltage-clamp conditions were studied at various wavelengths between 500 and 800 nm using unpolarized light . Our results indicate that the absor...

متن کامل

Optical signals from surface and T system membranes in skeletal muscle fibers. Experiments with the potentiometric dye NK2367

Absorbance signals were recorded from cut single skeletal muscle fibers stained with the nonpenetrating potentiometric dye NK2367 and mounted in a three-vaseline-gap voltage clamp. The characteristics of the optical signals recorded under current and voltage-clamp conditions were studied at various wavelengths between 500 and 800 nm using unpolarized light. Our results indicate that the absorba...

متن کامل

Voltage-dependent calcium release in human malignant hyperthermia muscle fibers.

Malignant hyperthermia (MH) results from a defect of calcium release control in skeletal muscle that is often caused by point mutations in the ryanodine receptor gene (RYR1). In malignant hyperthermia-susceptible (MHS) muscle, calcium release responds more sensitively to drugs such as halothane and caffeine. In addition, experiments on the porcine homolog of malignant hyperthermia (mutation Arg...

متن کامل

Differential effects of tetracaine on charge movements and Ca2+ signals in frog skeletal muscle

The effects of tetracaine on charge movements and on antipyrylazo III signals monitoring intracellular delta [Ca2+] were compared in cut frog semitendinosus muscle fibers in a single vaseline gap-voltage clamp. Low tetracaine concentrations (25-40 microM) markedly reduced delta [Ca2+] signals and shifted the rheobase. However, they neither influenced charge movement nor that peak delta [Ca2+] v...

متن کامل

Effect of thymol on kinetic properties of Ca and K currents in rat skeletal muscle

BACKGROUND Thymol is widely used as a general antiseptic and antioxidant compound in the medical practice and industry, and also as a stabilizer to several therapeutic agents, including halothane. Thus intoxication with thymol may occur in case of ingestion or improper anesthesia. In the present study, therefore, concentration-dependent effects of thymol (30-600 micro-grams) were studied on cal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of General Physiology

دوره 67  شماره 

صفحات  -

تاریخ انتشار 1976