Influence of flickering light on the retinal vessels in diabetic patients.
نویسندگان
چکیده
OBJECTIVE Stimulation of the retina with flickering light increases retinal vessel diameters in humans. Nitric oxide is a mediator of the retinal vasodilation to flicker. The reduction of vasodilation is considered an endothelial dysfunction. We investigated the response of retinal vessels to flickering light in diabetic patients in different stages of diabetic retinopathy. RESEARCH DESIGN AND METHODS We studied 53 healthy volunteers, 68 type 1 diabetic patients, and 172 type 2 diabetic patients. The diameter of retinal vessels was measured continuously online with the Dynamic Vessel Analyzer (DVA). Diabetic retinopathy was classified using Early Treatment Diabetic Retinopathy Study criteria. Changes in vasodilation are expressed as percent change over baseline values. RESULTS After adjustments for age, sex, and antihypertensive treatment, the response of retinal arterioles to diffuse luminance flicker was significantly diminished in patients with type 1 diabetes compared with healthy volunteers. The vasodilation of retinal arterioles and venules decreased continuously with increasing stages of diabetic retinopathy. The retinal arterial diameter change was 3.6 +/- 2.1% in the control group, 2.6 +/- 2.5% in the no diabetic retinopathy group, 2.0 +/- 2.7% in the mild nonproliferative diabetic retinopathy (NPDR) group, 1.6 +/- 2.2% in the moderate NPDR group, 1.8 +/- 1.9% in severe NPDR group, and 0.8 +/- 1.6% in proliferative diabetic retinopathy group. CONCLUSIONS Flicker responses of retinal vessels are abnormally reduced in diabetic patients. This decreased response deteriorated with increasing stages of retinopathy. The response was already reduced before clinical appearance of retinopathy. The noninvasive testing of retinal autoregulation with DVA might prove to be of value in early detection of diabetic vessel pathological changes.
منابع مشابه
COMMENTS AND RESPONSES Influence of Flickering Light on the Retinal Vessels in Diabetic Patients
W e thank Wong et al. (1) for their interest in our study (2) in which we showed that retinal vessels in diabetic patients with increasing stages of diabetic retinopathy experience a continuously decreasing response to flickering light. We believe that the issue raised by Wong et al. is very important. The study by Nguyen et al. (3) showed that arteriolar and venular calibers are structurally l...
متن کاملReduced retinal vessel response to flicker stimulation but not to exogenous nitric oxide in type 1 diabetes.
PURPOSE Various studies have shown that retinal vessels in patients with diabetes mellitus have a reduced capacity to adapt to changes in perfusion pressure and to stimulation with flickering light. Structural and functional changes in retinal vessels in diabetes could lead to a general reduction of vasodilator and/or vasoconstrictor capacity. To gain more insight into this topic, we compared t...
متن کاملDynamic responses in retinal vessel caliber with flicker light stimulation in eyes with diabetic retinopathy.
PURPOSE This study investigated the responses of retinal vessels to flickering light in diabetic patients with various stages of diabetic retinopathy (DR). METHODS This cross-sectional observational study evaluated adult subjects with diabetes mellitus. The Dynamic Vessel Analyzer (DVA) was used to measure retinal vascular dilatation in response to diffuse illuminance flicker. Diabetic retino...
متن کاملComparison of retinal vasodilator and constrictor responses in type 2 diabetes.
PURPOSE The retinal blood vessels provide a unique way to directly examine the human microvasculature, which is frequently damaged in individuals with diabetes. Previous studies have demonstrated that retinal flickering light-induced vasodilation and hyperoxia-induced vasoconstriction may operate by enhancing or reducing similar vasoregulatory factor(s), but a comparison between these two provo...
متن کاملAminoguanidine Reverses the Loss of Functional Hyperemia in a Rat Model of Diabetic Retinopathy
Flickering light dilates retinal arterioles and increases retinal blood flow, a response termed functional hyperemia. This response is diminished in diabetic patients even before the appearance of overt clinical retinopathy. The loss of functional hyperemia could deprive retinal neurons of oxygen and nutrients, possibly exacerbating the development of diabetic retinopathy. We have tested whethe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Diabetes care
دوره 31 6 شماره
صفحات -
تاریخ انتشار 2007