Autocalibration of accelerometer data for free-living physical activity assessment using local gravity and temperature: an evaluation on four continents
نویسندگان
چکیده
Wearable acceleration sensors are increasingly used for the assessment of free-living physical activity. Acceleration sensor calibration is a potential source of error. This study aims to describe and evaluate an autocalibration method to minimize calibration error using segments within the free-living records (no extra experiments needed). The autocalibration method entailed the extraction of nonmovement periods in the data, for which the measured vector magnitude should ideally be the gravitational acceleration (1 g); this property was used to derive calibration correction factors using an iterative closest-point fitting process. The reduction in calibration error was evaluated in data from four cohorts: UK (n = 921), Kuwait (n = 120), Cameroon (n = 311), and Brazil (n = 200). Our method significantly reduced calibration error in all cohorts (P < 0.01), ranging from 16.6 to 3.0 mg in the Kuwaiti cohort to 76.7 to 8.0 mg error in the Brazil cohort. Utilizing temperature sensor data resulted in a small nonsignificant additional improvement (P > 0.05). Temperature correction coefficients were highest for the z-axis, e.g., 19.6-mg offset per 5°C. Further, application of the autocalibration method had a significant impact on typical metrics used for describing human physical activity, e.g., in Brazil average wrist acceleration was 0.2 to 51% lower than uncalibrated values depending on metric selection (P < 0.01). The autocalibration method as presented helps reduce the calibration error in wearable acceleration sensor data and improves comparability of physical activity measures across study locations. Temperature ultization seems essential when temperature deviates substantially from the average temperature in the record but not for multiday summary measures.
منابع مشابه
Classification of accelerometer wear and non-wear events in seconds for monitoring free-living physical activity
OBJECTIVE To classify wear and non-wear time of accelerometer data for accurately quantifying physical activity in public health or population level research. DESIGN A bi-moving-window-based approach was used to combine acceleration and skin temperature data to identify wear and non-wear time events in triaxial accelerometer data that monitor physical activity. SETTING Local residents in Sw...
متن کاملEffects of Some Thermo-Physical Parameters on Free Convective Heat and Mass Transfer over Vertical Stretching Surface at Absolute Zero
Effects of some thermo-physical parameters on free convective heat and mass transfer over a vertical stretching surface at lowest level of heat energy in the presence of suction is investigated. The viscosity of the fluid is assumed to vary as a linear function of temperature and thermal conductivity is assumed constant. A similarity transformation is applied to reduce the governing equations i...
متن کاملReview and Comparison of In-field Calibration Methods of Accelerometer Based on Gravity Vector
Considering the wide applications of accelerometers to determine position and attitude and due to reducing of accuracy of this sensors because of some errors, this paper discusses the calibration of accelerometers. Also because the traditional calibration methods are very time consuming, costly and need precision laboratory equipment, in-field calibration methods are recommended which are simpl...
متن کاملAssessment of Storage and Temperature on Egg Physical Qualities for Peak Production in Hyline Chickens
The aim of the study was to evaluate the effect of storage and temperature on egg physical quality in Hyline chickens line. A total of 150 eggs from College of Natural Resources farm were sampled for the present experiment. About 70 eggs each were stored in home refrigerator (temperature, 7.46±0.23 ˚C; relative humidity, 24.80±0.05%) and room temperature (temperature, 22.98±1.12 ˚C; relative hu...
متن کاملGravity acceleration at the sea surface derived from satellite altimetry data using harmonic splines
Gravity acceleration data have grand pursuit for marine applications. Due to environmental effects, marine gravity observations always hold a high noise level. In this paper, we propose an approach to produce marine gravity data using satellite altimetry, high-resolution geopotential models and harmonic splines. On the one hand, harmonic spline functions have great capability for local gravity ...
متن کامل